


{"id":39256,"date":"2026-11-17T04:19:56","date_gmt":"2026-11-16T20:19:56","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/?p=39256"},"modified":"2026-11-17T04:45:33","modified_gmt":"2026-11-16T20:45:33","slug":"vna-high-impedance-measurement","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/","title":{"rendered":"VNA High Impedance Measurement: When S11 Misleads"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#VNA_Impedance_Measurement_What_Counts_as_High\" >VNA Impedance Measurement: What Counts as High?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Reflection_Coefficient_to_Impedance_Keep_the_Complex_Sign\" >Reflection Coefficient to Impedance: Keep the Complex Sign<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#S11_Measurement_Using_Network_Analyzer_A_Near-Open_Error_Example\" >S11 Measurement Using Network Analyzer: A Near-Open Error Example<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Reflection_vs_Series_Through_vs_Shunt_Through\" >Reflection vs. Series Through vs. Shunt Through<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Series_Through_Impedance_Measurement_Recalculate_With_S21\" >Series Through Impedance Measurement: Recalculate With S21<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#VNA_Calibration_Procedure_Put_the_Reference_at_the_DUT\" >VNA Calibration Procedure: Put the Reference at the DUT<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Fixture_Parasitic_Capacitance_A_High-Impedance_Trap\" >Fixture Parasitic Capacitance: A High-Impedance Trap<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#High_Impedance_Test_Report_Decide_Whether_the_Number_Is_Defensible\" >High Impedance Test Report: Decide Whether the Number Is Defensible<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#VNA_High_Impedance_Measurement_FAQs\" >VNA High Impedance Measurement FAQs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Technical_References\" >Technical References<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#Custom_RF_PCBs_With_Stackup_and_Coupon_Review\" >Custom RF PCBs With Stackup and Coupon Review<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div><p><strong>When a VNA sees an almost open circuit, a small error in the measured reflection can become a large error in the calculated impedance.<\/strong> Start with a calibrated one-port measurement at the DUT plane. If the impedance changes too much when you repeat the setup, try a validated series-through fixture for a suitable floating component. If neither method resolves the required range, report a bound or repeat with a better fixture instead of quoting a precise value.<\/p>\n<p>The goal is to distinguish the device from an open, not just to display an impedance on the Smith chart. Use complex measurements and an independent reference near the range you intend to report.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-high-impedance-measurement.jpg\" width=\"1200\" height=\"600\" alt=\"Two-port PCB test coupon with a series component between coax launches\" style=\"display:block;max-width:100%;height:auto\"><figcaption>On a series-through coupon, the component interrupts the signal path. This view is illustrative, not a fixture design specification.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Impedance_Measurement_What_Counts_as_High\"><\/span>VNA Impedance Measurement: What Counts as High?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>High means large relative to the reference impedance and hard to distinguish with the particular fixture, frequency and uncertainty. There is no universal cutoff in ohms. A 1 k\u03a9 resistor measured against 50 \u03a9 already brings the reflection close to +1, but whether it is reportable depends on how accurately the actual setup can resolve the difference from an open.<\/p>\n<p>Define the device, band, and reference plane. A high-impedance node connected to ground elsewhere cannot simply be placed between two VNA ports as a floating series element. A component measured in isolation is also not necessarily equivalent to its impedance in the assembled circuit.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Reflection_Coefficient_to_Impedance_Keep_the_Complex_Sign\"><\/span>Reflection Coefficient to Impedance: Keep the Complex Sign<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For a one-port measurement with real reference impedance Z<sub>0<\/sub>, <strong>Z = Z<sub>0<\/sub> \u00d7 (1 + \u0393) \u00f7 (1 \u2212 \u0393)<\/strong>, where \u0393 is complex S11 at the chosen plane. Use both magnitude and phase or real and imaginary data. In a 50 \u03a9 system, \u0393 = +0.90476 represents about 1 k\u03a9, but \u0393 = \u22120.90476 represents about 2.50 \u03a9. Identical reflection magnitude cannot distinguish them.<\/p>\n<p>An ideal open has \u0393 = +1 and an ideal short \u0393 = \u22121. Do not convert a magnitude-only return-loss chart to ohms by assuming one sign. Also check the file&#8217;s reference impedance and the actual measurement planes before comparing values from two setups.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"S11_Measurement_Using_Network_Analyzer_A_Near-Open_Error_Example\"><\/span>S11 Measurement Using Network Analyzer: A Near-Open Error Example<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Consider an ideal 1 k\u03a9 resistor in a 50 \u03a9 system. Its calculated reflection is approximately +0.90476. If the real part were read 0.01 lower or higher with no imaginary error, the conversion would give <strong>900 \u03a9 or 1.123 k\u03a9<\/strong>. These are hypothetical endpoints for one error assumption. Both phase and magnitude can move in a real sweep.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/near-open-impedance-example.jpg\" width=\"1200\" height=\"600\" alt=\"Reflection coefficient perturbations around 0.90476 convert to approximately 900, 1000, and 1123 ohms\" style=\"display:block;max-width:100%;height:auto\"><figcaption>Equal changes in the real reflection coefficient do not create equal changes in calculated impedance. The denominator shrinks as \u0393 approaches +1.<\/figcaption><\/figure>\n<p>For a primarily resistive load, the local sensitivity dZ\/d\u0393 is 2Z<sub>0<\/sub> \u00f7 (1 \u2212 \u0393)<sup>2<\/sup>. That explains why residual calibration errors, an imperfect open or a shifted fixture plane can dominate the reading. Near an open, admittance may be better behaved numerically, but it does not recover information your measurement did not resolve.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Reflection_vs_Series_Through_vs_Shunt_Through\"><\/span>Reflection vs. Series Through vs. Shunt Through<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Select the fixture by impedance range and the physical node<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Method<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Use when<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Validate before use<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">One-port reflection<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">You need input impedance at one defined port and can resolve its complex reflection.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Check open, fixture and a separate known reference. Near +1, verify that uncertainty still permits the required decision.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Two-port series through<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">The device can be inserted as an isolated series element and transmission is above the reliable floor.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Check an open gap for residual feedthrough and use an independently characterized series reference.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Two-port shunt through<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">A low impedance to the common return is the quantity of interest.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Qualify return paths and fixture residuals. A very high shunt impedance barely alters transmission.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Series_Through_Impedance_Measurement_Recalculate_With_S21\"><\/span>Series Through Impedance Measurement: Recalculate With S21<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For equal, real 50 \u03a9 reference impedances and a single lumped series impedance Z between the planes, <strong>S21 = 100 \u03a9 \u00f7 (100 \u03a9 + Z)<\/strong>. Invert the complex value to obtain Z = 100 \u03a9 \u00d7 (1\/S21 \u2212 1). A 1 k\u03a9 pure resistance gives S21 \u2248 0.09091, or <strong>\u221220.83 dB<\/strong>.<\/p>\n<p>If only the transmission magnitude varies by \u00b10.10 dB in this ideal example, with phase fixed, the reported resistance becomes about 987\u20131013 \u03a9. Do not compare that range directly with the earlier reflection example as if the two assumed errors were measured on the same setup. At sufficiently high impedance, feedthrough, receiver noise or a parasitic path around the DUT can dominate S21. Use the measured residual and required uncertainty, not a universal impedance boundary.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Procedure_Put_the_Reference_at_the_DUT\"><\/span>VNA Calibration Procedure: Put the Reference at the DUT<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Set the frequency range, power and receiver settings for the intended test. Calibrate to the needed planes or apply a justified fixture compensation or de-embedding procedure, then verify with a device the calibration did not use. A calibration at the coax faces does not automatically remove the launch, traces or gap pads. If the task is instead to verify a rail-to-return value in milliohms, use the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/two-port-shunt-through-pdn-impedance\/\">two-port shunt-through PDN impedance guide<\/a> to check the ground return and fixture residual. Make sure a recommended series or shunt workflow is supported by the instrument.<\/p>\n<p>For a series fixture, check the open gap and then a characterized component near the expected impedance. Keep the fixture and component plane consistent, and inspect the residual transmission over the whole required band. If the measured DUT response approaches that residual, a simple subtraction of magnitudes is not a valid correction. For related modeling work, see the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/s-parameter-dc-extrapolation\/\">S-parameter DC extrapolation guide<\/a> for why a finite-frequency result does not establish DC behavior.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Fixture_Parasitic_Capacitance_A_High-Impedance_Trap\"><\/span>Fixture Parasitic Capacitance: A High-Impedance Trap<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Suppose a nominal 1 k\u03a9 resistor has an additional <strong>0.2 pF<\/strong> across it in the measurement fixture. In a simple parallel model, Z = 1 \u00f7 (1\/R + j2\u03c0fC). At 100 MHz, that produces approximately <strong>984 \u2212 j124 \u03a9<\/strong>. This calculation is not a claim about common fixture capacitance or a particular resistor; it shows how an unmodeled path can turn an apparently resistive result into a complex one.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/high-impedance-fixture-parasitic.jpg\" width=\"1200\" height=\"600\" alt=\"One-kilohm resistor and an illustrative fixture capacitance of 0.2 picofarads in parallel across the measurement gap\" style=\"display:block;max-width:100%;height:auto\"><figcaption>Both branches are across the same two points. A real fixture may also have series parasitics and distributed coupling.<\/figcaption><\/figure>\n<p>For a component tolerance check, compare impedance with a valid independent reference over the same band and bias. For a high-impedance board node, verify that mounting, nearby copper and bias conditions represent the actual use. If the intended result is DC resistance, avoid reporting a VNA-derived extrapolation as a direct DC measurement.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"High_Impedance_Test_Report_Decide_Whether_the_Number_Is_Defensible\"><\/span>High Impedance Test Report: Decide Whether the Number Is Defensible<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Method choice and reporting worksheet<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Checkpoint<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Record<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Example one-port decision<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Target 1 k\u03a9 \u00b15%; assumed real \u0393 uncertainty \u00b10.01 gives 900\u20131123 \u03a9.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">That range cannot prove 950\u20131050 \u03a9. Qualify another method with an independent reference.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Independent validation<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Planes, fixture ID, grounding, open-gap response, known device response, reconnection repeats and band.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">If the DUT is indistinguishable from the residual, qualify a bounded statement or remeasure. Do not invent precision.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Release format<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Complex Z or admittance versus frequency, actual limits, bias, applicable uncertainty and decision rule.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Apply the agreed electrical criterion; no generic IPC requirement sets the usable VNA high-impedance range.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"VNA_High_Impedance_Measurement_FAQs\"><\/span>VNA High Impedance Measurement FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>Can I get impedance from S11 in dB alone?<\/h3>\n<p>No. Include phase or both real and imaginary parts, and use the stated reference impedance.<\/p>\n<h3>Why does S11 change very little near an open?<\/h3>\n<p>Different large impedances can all reflect nearly all the incident signal with similar phase. The inverse conversion magnifies the small differences.<\/p>\n<h3>Can I use series through for a grounded board node?<\/h3>\n<p>Not as the simple floating series fixture shown here. Use a method compatible with its actual return and bias paths.<\/p>\n<h3>Does a low-noise trace prove the result is correct?<\/h3>\n<p>No. Fixture feedthrough, reference-plane errors and calibration residuals can remain stable.<\/p>\n<h3>Can I remove the open fixture trace by subtracting dB?<\/h3>\n<p>Not as a general correction. Use the approved complex fixture model or calibration method and confirm it on an independent reference.<\/p>\n<h3>Does series through always improve the high end?<\/h3>\n<p>No. It depends on fixture isolation, usable received level, device grounding, and the chosen band.<\/p>\n<h3>What if a one-port conversion reports a negative resistance?<\/h3>\n<p>For an expected passive resistor, check residual errors, calibration and uncertainty before assigning a physical meaning to the result.<\/p>\n<h3>Should I report one nominal value or a sweep?<\/h3>\n<p>Use the specified frequency or band. Report complex impedance, the plane and uncertainty rather than extending a single value to untested conditions.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Technical_References\"><\/span>Technical References<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a rel=\"nofollow\" href=\"https:\/\/helpfiles.keysight.com\/csg\/e5061b\/quick_start_guide\/impedance_measurement\/measurement_procedure.htm\">Keysight E5061B: Impedance Measurement Method<\/a> \u2014 reflection, series and shunt method boundaries.<\/li>\n<li><a rel=\"nofollow\" href=\"https:\/\/helpfiles.keysight.com\/csg\/pxivna\/S4_Collect\/Performing_Parameter_Conversion_of_Measurement_Results.htm\">Keysight: Performing Parameter Conversion<\/a> \u2014 reflection and transmission impedance representations.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Custom_RF_PCBs_With_Stackup_and_Coupon_Review\"><\/span>Custom RF PCBs With Stackup and Coupon Review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Need a new RF PCB or impedance test coupon? Ask EBest Circuit to review the stackup, coax launches and coupon geometry before quoting. Marking the actual measurement plane and intended fixture early helps avoid a coupon that cannot distinguish the component from its surroundings.<\/p>\n<p>Send your Gerbers, stackup, operating band, required coupon and quantities to <a href=\"mailto:sales@bestpcbs.com\">sales@bestpcbs.com<\/a>. <strong>Request a custom RF PCB quote and tell us what the coupon needs to verify.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.<\/p>\n","protected":false},"author":32827,"featured_media":39254,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[174],"tags":[9214,9452,8862],"class_list":["post-39256","post","type-post","status-publish","format-standard","hentry","category-bestpcb","tag-s-parameters","tag-vna-calibration","tag-vna-s21-measurement"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"mingling, gong\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"VNA High Impedance Measurement: When S11 Misleads - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta property=\"og:description\" content=\"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-16T20:19:56+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-16T20:45:33+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"VNA High Impedance Measurement: When S11 Misleads - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#blogposting\",\"name\":\"VNA High Impedance Measurement: When S11 Misleads - PCB & MCPCB - EBest PCB\",\"headline\":\"VNA High Impedance Measurement: When S11 Misleads\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-high-impedance-measurement-feature.jpg\",\"width\":1200,\"height\":600},\"datePublished\":\"2026-11-17T04:19:56+08:00\",\"dateModified\":\"2026-11-17T04:45:33+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#webpage\"},\"articleSection\":\"bestpcb, S Parameters, vna calibration, VNA S21 Measurement\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"position\":2,\"name\":\"bestpcb\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#listItem\",\"name\":\"VNA High Impedance Measurement: When S11 Misleads\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#listItem\",\"position\":3,\"name\":\"VNA High Impedance Measurement: When S11 Misleads\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/\",\"name\":\"mingling, gong\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"mingling, gong\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/\",\"name\":\"VNA High Impedance Measurement: When S11 Misleads - PCB & MCPCB - EBest PCB\",\"description\":\"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-high-impedance-measurement-feature.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#mainImage\",\"width\":1200,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-high-impedance-measurement\\\/#mainImage\"},\"datePublished\":\"2026-11-17T04:19:56+08:00\",\"dateModified\":\"2026-11-17T04:45:33+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"VNA High Impedance Measurement: When S11 Misleads - PCB & MCPCB - EBest PCB","description":"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#blogposting","name":"VNA High Impedance Measurement: When S11 Misleads - PCB & MCPCB - EBest PCB","headline":"VNA High Impedance Measurement: When S11 Misleads","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-high-impedance-measurement-feature.jpg","width":1200,"height":600},"datePublished":"2026-11-17T04:19:56+08:00","dateModified":"2026-11-17T04:45:33+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#webpage"},"articleSection":"bestpcb, S Parameters, vna calibration, VNA S21 Measurement"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","position":2,"name":"bestpcb","item":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#listItem","name":"VNA High Impedance Measurement: When S11 Misleads"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#listItem","position":3,"name":"VNA High Impedance Measurement: When S11 Misleads","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/","name":"mingling, gong","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g","width":96,"height":96,"caption":"mingling, gong"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/","name":"VNA High Impedance Measurement: When S11 Misleads - PCB & MCPCB - EBest PCB","description":"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-high-impedance-measurement-feature.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#mainImage","width":1200,"height":600},"primaryImageOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/#mainImage"},"datePublished":"2026-11-17T04:19:56+08:00","dateModified":"2026-11-17T04:45:33+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"VNA High Impedance Measurement: When S11 Misleads - PCB &amp; MCPCB - EBest PCB","og:description":"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-11-16T20:19:56+00:00","article:modified_time":"2026-11-16T20:45:33+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"VNA High Impedance Measurement: When S11 Misleads - PCB &amp; MCPCB - EBest PCB","twitter:description":"Measure high impedance with a VNA. See why near-open S11 magnifies error, when series through helps, and how to verify the fixture.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"39256","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2026-11-16 20:20:08","updated":"2026-11-17 00:44:15","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/\" title=\"bestpcb\">bestpcb<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tVNA High Impedance Measurement: When S11 Misleads\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog\/"},{"label":"bestpcb","link":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/"},{"label":"VNA High Impedance Measurement: When S11 Misleads","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-high-impedance-measurement\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/32827"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=39256"}],"version-history":[{"count":2,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39256\/revisions"}],"predecessor-version":[{"id":39265,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39256\/revisions\/39265"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media\/39254"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=39256"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=39256"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=39256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}