


{"id":39249,"date":"2026-11-17T03:52:07","date_gmt":"2026-11-16T19:52:07","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/?p=39249"},"modified":"2026-11-17T03:52:07","modified_gmt":"2026-11-16T19:52:07","slug":"vna-calibration-drift","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/","title":{"rendered":"VNA Calibration Drift: Which PCB Results Can You Trust?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#Calibration_vs_Calibration_Verification_What_Each_One_Proves\" >Calibration vs Calibration Verification: What Each One Proves<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#VNA_Calibration_Standards_Pick_a_Separate_Check_Device\" >VNA Calibration Standards: Pick a Separate Check Device<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#VNA_Calibration_Procedure_Establish_the_Start-of-Run_Baseline\" >VNA Calibration Procedure: Establish the Start-of-Run Baseline<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#Measurement_Drift_Separate_Time_From_Physical_Movement\" >Measurement Drift: Separate Time From Physical Movement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#VNA_Calibration_Verification_Interval_Checks_vs_Triggered_Checks\" >VNA Calibration Verification: Interval Checks vs. Triggered Checks<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#Failed_VNA_Verification_Find_Which_Boards_to_Hold\" >Failed VNA Verification: Find Which Boards to Hold<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#VNA_Measurement_Uncertainty_Leave_Room_at_the_Limit\" >VNA Measurement Uncertainty: Leave Room at the Limit<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#After_a_Drift_Failure_Restore_the_Setup_Before_Retest\" >After a Drift Failure: Restore the Setup Before Retest<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#VNA_Calibration_Drift_FAQs\" >VNA Calibration Drift FAQs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#Technical_References\" >Technical References<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#Custom_RF_PCBs_With_Stackup_and_Test_Coupon_Review\" >Custom RF PCBs With Stackup and Test Coupon Review<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div><p><strong>A VNA calibration pass at the start of a shift does not prove it stayed valid for every board.<\/strong> Measure an independent check standard at the start and at defined checkpoints. If the last check fails, stop release, use the test timestamps to identify the potentially affected boards, and restore and verify the setup before retesting. Do not subtract one reference error from all PCB measurements.<\/p>\n<p>Use a check device that exercises the measurement that drives the decision. A well-matched attenuator can help track transmission loss, but it cannot automatically verify a weak reflection, a deep notch, or a different connector plane. Establish separate limits where those measurements matter.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-calibration-drift.jpg\" alt=\"Coaxial attenuator, RF test leads, and a two-port PCB coupon on a test bench\" width=\"1200\" height=\"600\" style=\"display:block;max-width:100%;height:auto\"><figcaption>Verify the same measurement system that will test the boards, at the same planes and settings. The pictured layout is illustrative.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Calibration_vs_Calibration_Verification_What_Each_One_Proves\"><\/span>Calibration vs Calibration Verification: What Each One Proves<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Calibration estimates correction terms using defined connections and standards. Verification asks whether the corrected system can measure an independent, suitable artifact as expected. A third step, tracking drift, compares repeated verification readings against an accepted baseline over time. It is possible for the first verification to pass and a later one to fail.<\/p>\n<p>Compare both with the reference characterization at the start and with the baseline later. A stable but wrong reading can pass a relative drift check. A reference check also measures the combined setup: the analyzer, adapters, cables, contacts and settings. It does not prove which component caused a shift.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Standards_Pick_a_Separate_Check_Device\"><\/span>VNA Calibration Standards: Pick a Separate Check Device<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Do not use the same open, short, load or thru assumed by the calibration as your sole evidence that the correction works. An independent two-port with characterized insertion loss and phase can check transmission. Use a suitable mismatch artifact when reflection matters, and an independently characterized lower-level path when a filter stopband approaches the system floor. A single device does not cover every error term or uncertainty.<\/p>\n<p>Make sure the reference planes, connector family and orientation match the setup or are explicitly accounted for. Compare on a supported frequency grid and log the selected metrics, band and reference uncertainty. For a narrowband filter, the worst point in the passband may matter more than the center frequency.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Procedure_Establish_the_Start-of-Run_Baseline\"><\/span>VNA Calibration Procedure: Establish the Start-of-Run Baseline<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ol>\n<li>Prepare the analyzer as specified by its manufacturer. Secure the cables, identify the calibration planes, and settle the artifact and setup in the conditions specified for your test plan.<\/li>\n<li>Calibrate on the intended frequency grid with the required kit definition and test settings. Save the correction state and identify any adapter already included.<\/li>\n<li>Attach the independent standard with the approved connection practice. Verify it against its characterized data and allowed uncertainty. If it fails now, do not make it the baseline.<\/li>\n<li>After it passes, save the raw complex readings, the initial reference trace, temperature, time and setup ID. Check repeatability with the expected reconnection procedure when the artifact must be removed for board testing.<\/li>\n<\/ol>\n<p>If the ports cannot mate, use the suitable workflow and independent check described in the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-unknown-thru-calibration\/\">Unknown Thru calibration guide<\/a> before establishing this baseline.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Measurement_Drift_Separate_Time_From_Physical_Movement\"><\/span>Measurement Drift: Separate Time From Physical Movement<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Leave a check artifact connected and repeat a short series without moving the setup. A gradual, reproducible shift suggests a time-dependent setup or environment effect; it does not identify the analyzer as the cause. If the shift appears only after moving a cable or reseating a connector, isolate that action using the same artifact and settings. If one artifact changes while another suitably chosen one remains stable, inspect the first artifact and verify that both checks exercise the relevant measurement.<\/p>\n<p>For a phase requirement, compare the shortest signed angular difference at each frequency rather than treating +179\u00b0 and \u2212179\u00b0 as 358\u00b0 apart. Check the shape across the band too if a delay change matters. For amplitude, define whether the report uses signed S21 in dB or positive insertion loss. In this article&#8217;s examples, insertion loss is positive and an increase means the measured path looks lossier.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-drift-bracket-example.jpg\" alt=\"Check standard drift at 0, 30, 60, and 90 minutes; only the 90-minute point exceeds the example 0.10 dB limit\" width=\"1200\" height=\"600\" style=\"display:block;max-width:100%;height:auto\"><figcaption>Four hypothetical checkpoint values, not a continuous drift measurement. A failed check flags the interval after the last known good check, not the exact instant drift began.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Verification_Interval_Checks_vs_Triggered_Checks\"><\/span>VNA Calibration Verification: Interval Checks vs. Triggered Checks<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use these checks together when the consequence of releasing a bad lot warrants it. Set the schedule from observed stability, reconnection repeatability and the size of an acceptable retest window. A vendor warm-up recommendation is not a calibrated test-window length.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Choose verification timing by the failure it catches<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Check<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Best use<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Limits and next action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Start and end of run<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Short, stable runs with an acceptable whole-run retest cost.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">A failed end check can put the entire run on hold if no intermediate evidence exists.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Periodic checkpoint<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Long RF coupon or filter runs where an intermediate check can locate affected work.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">More handling and test time. Compare against a stable fixture and documented repeatability.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Triggered re-verification<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">After an adapter change, cable movement, unexpected temperature shift, or other event that can invalidate the setup.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Do not rely on this alone; gradual drift can occur without a recorded trigger.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Failed_VNA_Verification_Find_Which_Boards_to_Hold\"><\/span>Failed VNA Verification: Find Which Boards to Hold<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use this worksheet for a serialized lot with reliable time stamps. In the hypothetical example at 10 GHz, the verified start value is 10.02 dB, and the maximum allowed absolute change from it is 0.10 dB. At 60 minutes, the reference reads 10.09 dB; at 90 minutes, 10.16 dB. The first is 0.07 dB from baseline and still passes; the second is 0.14 dB away and fails.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Retest worksheet: VNA drift example and decision<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Record<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Example entry<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Start baseline<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">0 min: 10.02 dB; independent absolute check already accepted.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Save the state and baseline. Apply the agreed 0.10 dB drift limit only to this example.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Last known good<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">30 min: 10.06 dB (+0.04). 60 min: 10.09 dB (+0.07).<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Use the 60-minute pass as the initial containment boundary only if setup and timestamps are reliable.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">First failed check<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">90 min: 10.16 dB (+0.14); the 0.10 dB allowance is exceeded.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Hold units measured after the last good check until the system passes again. Include earlier units if logs indicate intermittent failure or setup changes.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"white-space:normal;overflow-wrap:anywhere\">Restored setup<\/th>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Record adjustment, new calibration ID if applicable, independent pass and rerun results.<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Retest the identified units. Expand scope if timestamps or calibrated-state records do not support the boundary.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Measurement_Uncertainty_Leave_Room_at_the_Limit\"><\/span>VNA Measurement Uncertainty: Leave Room at the Limit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Set the allowable drift before testing, not after seeing the results. For illustration, a drawing allows a maximum of 1.00 dB loss at one frequency. A PCB measures 0.88 dB. If the validated decision rule allows for up to 0.10 dB of drift and another bounded 0.06 dB of error from distinct contributors, a conservative additive upper result is <strong>1.04 dB<\/strong>. That result cannot be released under this example. These are assumed bounds, not a universal uncertainty formula; follow the contractual decision rule and avoid counting the same contribution twice.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-drift-decision-margin.jpg\" alt=\"Measured insertion loss 0.88 dB and conservative upper result 1.04 dB exceeding an example 1.00 dB limit\" width=\"1200\" height=\"600\" style=\"display:block;max-width:100%;height:auto\"><figcaption>The nominal reading is below the example limit, but the upper decision bound crosses it. This calculation assumes a currently valid setup.<\/figcaption><\/figure>\n<p>If a verification check has already failed, this allowance is no longer evidence that the affected board result is valid. Retest on a verified setup. Also do not transfer a measured offset on a well-matched attenuator directly to an unmatched filter: their interactions with residual system errors can differ.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"After_a_Drift_Failure_Restore_the_Setup_Before_Retest\"><\/span>After a Drift Failure: Restore the Setup Before Retest<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record the failing trace, setup and serial numbers before any change. Check the connector condition and seating, cable position and instrument status. If the approved correction is invalid, recalibrate at the intended planes and run a separate verification again. Some analyzers offer a model-specific calibration update; follow the documented restrictions and still verify with an independent device.<\/p>\n<p><strong>RF coupon or filter acceptance:<\/strong> Use the verified setup to repeat the affected transmission and reflection checks over the contract band. Record both the original result and the retest, including which procedure authorizes final disposition. <strong>Comparative development tests:<\/strong> Re-run the reference and both board revisions at the same settings. Do not credit a design change if the verification shift could account for the observed improvement. No general PCB workmanship class sets a universal VNA drift allowance; use the instrument workflow and the agreed RF acceptance plan.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Drift_FAQs\"><\/span>VNA Calibration Drift FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>How often should I recheck the VNA?<\/h3>\n<p>Base the interval on stability evidence, required decision margin and how many units you can retest. Add triggered checks when the setup changes.<\/p>\n<h3>Do I need to recalibrate every time the check is repeated?<\/h3>\n<p>No. If the approved check still passes and the setup is unchanged, keep the correction under the agreed plan. An out-of-limit result needs investigation and a verified correction.<\/p>\n<h3>Can I simply reuse the calibration thru as my check?<\/h3>\n<p>It is a useful sanity check, but not independent evidence on its own. Use a suitable artifact not used to fit the correction.<\/p>\n<h3>Does a stable reference trace prove it is accurate?<\/h3>\n<p>No. It can stay stable while being biased. Establish the baseline against independently characterized data first.<\/p>\n<h3>What if only phase drifts?<\/h3>\n<p>Check the phase allowance, reference plane, and cable or adapter handling. A passing magnitude reading does not override a phase requirement.<\/p>\n<h3>Can I subtract the reference shift from every result?<\/h3>\n<p>Not without an approved model and independent verification showing that correction applies to the DUT and measurement. Ordinarily, hold and retest affected boards.<\/p>\n<h3>Does the first failed check tell me when the drift started?<\/h3>\n<p>No. It provides a detection time. Use the last valid check and the event history to define a conservative affected interval.<\/p>\n<h3>What must the test report keep?<\/h3>\n<p>Keep verification traces, baseline, settings, test and event times, serial numbers, limits and disposition so the affected interval can be reconstructed.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Technical_References\"><\/span>Technical References<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/helpfiles.keysight.com\/csg\/m9485a\/support\/system_verification.htm\" rel=\"nofollow\">Keysight M9485A: System Verification<\/a> \u2014 defined system scope and independently characterized devices.<\/li>\n<li><a href=\"https:\/\/www.nist.gov\/publications\/microwave-network-analyzers-discussion-verification-methods-0\" rel=\"nofollow\">NIST: Microwave Network Analyzers \u2013 A Discussion of Verification Methods<\/a> \u2014 check standard selection and verification approaches.<\/li>\n<li><a href=\"https:\/\/helpfiles.keysight.com\/csg\/pxivna\/S3_Cals\/Drift_Calibration.htm\" rel=\"nofollow\">Keysight PXI VNA: Cal Update<\/a> \u2014 instrument-specific correction update conditions.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Custom_RF_PCBs_With_Stackup_and_Test_Coupon_Review\"><\/span>Custom RF PCBs With Stackup and Test Coupon Review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Need a custom RF PCB or new test coupon? Ask EBest Circuit to review the stackup, launch geometry and coupon location before fabrication. Calling out the intended measurement plane and fixture at quoting gives the design and fabrication team a common basis for the RF evidence.<\/p>\n<p>Send your files, operating band, impedance targets, coupon requirements and quantities to <a href=\"mailto:sales@bestpcbs.com\">sales@bestpcbs.com<\/a>. <strong>Request a custom RF PCB quote and include the measurements your team must verify.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.<\/p>\n","protected":false},"author":32827,"featured_media":39245,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[174],"tags":[9214,9452,8862],"class_list":["post-39249","post","type-post","status-publish","format-standard","hentry","category-bestpcb","tag-s-parameters","tag-vna-calibration","tag-vna-s21-measurement"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"mingling, gong\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta property=\"og:description\" content=\"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-16T19:52:07+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-16T19:52:07+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#blogposting\",\"name\":\"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB & MCPCB - EBest PCB\",\"headline\":\"VNA Calibration Drift: Which PCB Results Can You Trust?\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-calibration-drift-feature.jpg\",\"width\":1200,\"height\":600},\"datePublished\":\"2026-11-17T03:52:07+08:00\",\"dateModified\":\"2026-11-17T03:52:07+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#webpage\"},\"articleSection\":\"bestpcb, S Parameters, vna calibration, VNA S21 Measurement\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"position\":2,\"name\":\"bestpcb\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#listItem\",\"name\":\"VNA Calibration Drift: Which PCB Results Can You Trust?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#listItem\",\"position\":3,\"name\":\"VNA Calibration Drift: Which PCB Results Can You Trust?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/\",\"name\":\"mingling, gong\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"mingling, gong\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/\",\"name\":\"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB & MCPCB - EBest PCB\",\"description\":\"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-calibration-drift-feature.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#mainImage\",\"width\":1200,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-calibration-drift\\\/#mainImage\"},\"datePublished\":\"2026-11-17T03:52:07+08:00\",\"dateModified\":\"2026-11-17T03:52:07+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB & MCPCB - EBest PCB","description":"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#blogposting","name":"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB & MCPCB - EBest PCB","headline":"VNA Calibration Drift: Which PCB Results Can You Trust?","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-calibration-drift-feature.jpg","width":1200,"height":600},"datePublished":"2026-11-17T03:52:07+08:00","dateModified":"2026-11-17T03:52:07+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#webpage"},"articleSection":"bestpcb, S Parameters, vna calibration, VNA S21 Measurement"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","position":2,"name":"bestpcb","item":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#listItem","name":"VNA Calibration Drift: Which PCB Results Can You Trust?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#listItem","position":3,"name":"VNA Calibration Drift: Which PCB Results Can You Trust?","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/","name":"mingling, gong","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g","width":96,"height":96,"caption":"mingling, gong"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/","name":"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB & MCPCB - EBest PCB","description":"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-calibration-drift-feature.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#mainImage","width":1200,"height":600},"primaryImageOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/#mainImage"},"datePublished":"2026-11-17T03:52:07+08:00","dateModified":"2026-11-17T03:52:07+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB &amp; MCPCB - EBest PCB","og:description":"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-11-16T19:52:07+00:00","article:modified_time":"2026-11-16T19:52:07+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"VNA Calibration Drift: Which PCB Results Can You Trust? - PCB &amp; MCPCB - EBest PCB","twitter:description":"Track VNA calibration drift with independent checks. Set a drift allowance, identify affected RF PCB results, and know which boards to retest.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"39249","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2026-11-16 19:52:18","updated":"2026-11-17 00:44:14","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/\" title=\"bestpcb\">bestpcb<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tVNA Calibration Drift: Which PCB Results Can You Trust?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog\/"},{"label":"bestpcb","link":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/"},{"label":"VNA Calibration Drift: Which PCB Results Can You Trust?","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-calibration-drift\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/32827"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=39249"}],"version-history":[{"count":1,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39249\/revisions"}],"predecessor-version":[{"id":39250,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39249\/revisions\/39250"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media\/39245"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=39249"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=39249"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=39249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}