


{"id":39235,"date":"2026-11-17T02:49:34","date_gmt":"2026-11-16T18:49:34","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/?p=39235"},"modified":"2026-11-17T03:23:42","modified_gmt":"2026-11-16T19:23:42","slug":"cascading-s-parameters","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/","title":{"rendered":"Cascading S-Parameters: When Adding Loss in dB Fails"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Cascading_S-Parameters_What_Are_You_Connecting\" >Cascading S-Parameters: What Are You Connecting?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#S-Parameter_Cascade_Formula_Include_the_Interface_Reflections\" >S-Parameter Cascade Formula: Include the Interface Reflections<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Insertion_Loss_Calculation_How_Much_Can_Adding_dB_Miss\" >Insertion Loss Calculation: How Much Can Adding dB Miss?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#S-Parameters_to_ABCD_Conversion_vs_Direct_Network_Connection\" >S-Parameters to ABCD Conversion vs. Direct Network Connection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Touchstone_File_Align_Frequency_Port_Order_and_Reference_Impedance\" >Touchstone File: Align Frequency, Port Order and Reference Impedance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#How_to_Verify_a_Cascaded_S-Parameter_Model_on_the_Bench\" >How to Verify a Cascaded S-Parameter Model on the Bench<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Where_to_Use_a_Two-Port_Cascade_in_PCB_Engineering\" >Where to Use a Two-Port Cascade in PCB Engineering<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#How_to_Release_a_Cascaded_Network_for_Simulation\" >How to Release a Cascaded Network for Simulation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Cascading_S-Parameters_FAQs\" >Cascading S-Parameters FAQs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Technical_References\" >Technical References<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#Custom_High-Speed_PCBs_With_Stackup_and_Coupon_Review\" >Custom High-Speed PCBs With Stackup and Coupon Review<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div><p><strong>Do not add the insertion loss of two PCB blocks in dB unless the reflections at their joint are small enough for your error budget.<\/strong> Join the full complex two-port models first. In the example below, the same two forward-transmission magnitudes predict 6.20 dB of loss if you add them, but the complete model gives 5.38 dB or 6.94 dB depending on the reflection phase. None of those figures is measured board data.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/cascading-s-parameters.jpg\" width=\"1200\" height=\"600\" alt=\"Two separate RF PCB test coupons connected in a physical cascade\" style=\"max-width:100%;height:auto;display:block\"><figcaption>The modeled joint must be the joint on the bench. A connector or adapter at that joint must be represented once, not twice.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Cascading_S-Parameters_What_Are_You_Connecting\"><\/span>Cascading S-Parameters: What Are You Connecting?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A cascade puts the output of network A into the input of network B. The wave transmitted by A travels toward B, and a wave reflected from B travels back toward A. If both internal ports reflect, some of that wave makes repeated trips across the interface. The combined transmission depends on both the loss through each network and the complex size and phase of those returning waves.<\/p>\n<p>Draw the port order, joint and exterior reference planes before opening either S2P file. If A and B were measured with the same removable coax launch attached, their separate measurements might include duplicate hardware. Do not join those files as though the shared launch were a zero-length joint. Decide whether the physical connector or transition belongs inside A, inside B, or in a separate measured block.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"S-Parameter_Cascade_Formula_Include_the_Interface_Reflections\"><\/span>S-Parameter Cascade Formula: Include the Interface Reflections<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For two directly joined two-ports at the same frequency, with connected waves on compatible real reference impedances and consistent normalization, the total forward transmission is:<\/p>\n<p><strong>S<sub>21,total<\/sub> = A<sub>21<\/sub>B<sub>21<\/sub> \u00f7 (1 \u2212 A<sub>22<\/sub>B<sub>11<\/sub>)<\/strong>.<\/p>\n<p>With no incident wave at the output of B, the wave coming back into A equals the wave entering B multiplied by B<sub>11<\/sub>. At A&#8217;s output, the forward wave is the direct contribution from A<sub>21<\/sub> plus that returning wave multiplied by A<sub>22<\/sub>. Substituting one relation into the other gives the denominator. If one internal port is perfectly matched, the product A<sub>22<\/sub>B<sub>11<\/sub> is zero and the simple S<sub>21<\/sub> multiplication is exact under these assumptions.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/cascade-interface-reflections.jpg\" width=\"1200\" height=\"600\" alt=\"Two connected S-parameter blocks with internal reflections A22 and B11 and forward signal crossing from A to B\" loading=\"lazy\" style=\"max-width:100%;height:auto;display:block\"><figcaption>Use A&#8217;s output reflection and B&#8217;s input reflection at the connected planes. Keep any separate electrical length in its own modeled block.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Insertion_Loss_Calculation_How_Much_Can_Adding_dB_Miss\"><\/span>Insertion Loss Calculation: How Much Can Adding dB Miss?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In a hypothetical calculation at one frequency, let both forward-transmission magnitudes be 0.70, and let the two internal reflection magnitudes be 0.30, or about 10.46 dB return loss each. The product estimate is 0.49, giving S<sub>21<\/sub> = \u22126.20 dB in magnitude notation (positive insertion loss of 6.20 dB).<\/p>\n<p>Now include phase. If A<sub>22<\/sub>B<sub>11<\/sub> = +0.09, the magnitude is 0.49 \u00f7 0.91 = 0.5385, giving <strong>5.38 dB insertion loss<\/strong>. If the reflection product is \u22120.09, its magnitude is unchanged, but the result is 0.49 \u00f7 1.09 = 0.4495, giving <strong>6.94 dB insertion loss<\/strong>. The shortcut missed by about 0.82 dB in the first case and 0.75 dB in the second, using unrounded results. That is material in a 0.50 dB modeling budget but may be acceptable for a rough estimate with a looser budget.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/cascade-mismatch-loss.jpg\" width=\"1200\" height=\"600\" alt=\"Example comparison of 5.38 dB for in-phase reflection, 6.20 dB for adding loss, and 6.94 dB for opposite-phase reflection\" loading=\"lazy\" style=\"max-width:100%;height:auto;display:block\"><figcaption>Calculated results for the same magnitudes and different interface phases. A larger return-loss number means a smaller reflection magnitude.<\/figcaption><\/figure>\n<p>If the phase is not known and the reflection-product magnitude is <em>r<\/em> &lt; 1, the denominator magnitude lies between 1 \u2212 <em>r<\/em> and 1 + <em>r<\/em>. Bound the shortcut error across the whole band before using it. If that bound consumes your allowed margin, use the complex cascade and verify it.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"S-Parameters_to_ABCD_Conversion_vs_Direct_Network_Connection\"><\/span>S-Parameters to ABCD Conversion vs. Direct Network Connection<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Do not multiply the raw S matrices as though they were transfer matrices. The variables sit on different sides of the network. Chain matrices such as ABCD can be multiplied in physical order when the input, output and current conventions match. Or use a library&#8217;s direct network connection with explicit ports, which avoids manually choosing a matrix convention.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Three approaches to cascading or estimating a two-port chain<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Approach<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Use when<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Check before trusting it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Add loss in dB<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Getting a first estimate for well-matched stages<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Bound reflection error against the modeling budget. No return-loss prediction.<\/td>\n<\/tr>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">ABCD or chain matrices<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Cascading compatible two-ports in a documented convention<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Confirm order and conversion, especially near very small S<sub>21<\/sub>, where common conversion formulas can be poorly conditioned.<\/td>\n<\/tr>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Direct complex connection<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Using a library with known port and impedance handling<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Verify the connection map, normalization and frequency alignment. Compare with an independent assembly measurement.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Touchstone_File_Align_Frequency_Port_Order_and_Reference_Impedance\"><\/span>Touchstone File: Align Frequency, Port Order and Reference Impedance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Confirm the file&#8217;s frequency unit, port mapping, complex representation and reference impedance. Decide what reference planes the measured blocks include. A 50 \u03a9 file and a 75 \u03a9 file do not establish the geometry of a real transition; normalize or connect the full networks with a method that handles their reference impedances. Include a physical transition separately if it is part of the assembly you intend to predict.<\/p>\n<p>Use the shared measured band and a documented frequency grid. Avoid extending a file outside its valid band to make the points line up. If a solver needs new points, apply the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/s-parameter-interpolation\/\">S-parameter interpolation checks<\/a> before joining the models. Near a notch, a sweep that misses the feature cannot be repaired by adding more display points.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Verify_a_Cascaded_S-Parameter_Model_on_the_Bench\"><\/span>How to Verify a Cascaded S-Parameter Model on the Bench<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Measure the physically joined chain with the same exterior planes, port directions and frequency band as the model. Plot the complex residuals for forward and reverse transmission and the relevant reflections. A close S<sub>21<\/sub> magnitude at one frequency can hide a wrong phase slope, a flipped block or a fixture error. Save the independent assembly file with the model.<\/p>\n<figure class=\"wp-block-table\" style=\"max-width:100%;overflow-x:auto\">\n<table style=\"table-layout:fixed;width:100%\">\n<caption>Worked assembly comparison; values and limits are illustrative<\/caption>\n<thead>\n<tr>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Item<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Example residual<\/th>\n<th scope=\"col\" style=\"white-space:normal;overflow-wrap:anywhere\">Interpretation and next step<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Insertion loss<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Model 5.38 dB; assembly 5.56 dB; difference 0.18 dB<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Within the 0.25 dB example limit if the agreed uncertainty rule is satisfied.<\/td>\n<\/tr>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Transmission phase<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Model \u221270\u00b0; assembly \u221261\u00b0; difference +9\u00b0<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Outside the 5\u00b0 example limit. Check the reference planes, connector delays and file orientation.<\/td>\n<\/tr>\n<tr>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Reflection or reverse path<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Compare relevant S<sub>11<\/sub>, S<sub>22<\/sub> and S<sub>12<\/sub> across the critical band<\/td>\n<td style=\"white-space:normal;overflow-wrap:anywhere\">Not proven by the first two rows. Use the actual limits and retain the measured file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Where_to_Use_a_Two-Port_Cascade_in_PCB_Engineering\"><\/span>Where to Use a Two-Port Cascade in PCB Engineering<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Cable plus RF board:<\/strong> Use the cable and board files to estimate loss and phase at the system interfaces. Include any adapter once. Verify total response at the intended cable position across the operating band; a changed cable route can invalidate the comparison.<\/p>\n<p><strong>Connector launch plus PCB trace:<\/strong> Place the join at defined geometry, not at a vague connector boundary. Check the return loss and phase as well as insertion loss. If adjacent structures couple directly across the supposed boundary, measure or simulate the combination instead of assuming independent two-ports.<\/p>\n<p><strong>Filter plus another RF stage:<\/strong> Check passband ripple and stopband rejection as separate tasks. A good two-port fit in the passband does not prove a deep stopband result near the instrument&#8217;s noise floor. Verify any notch that determines whether the design passes.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_to_Release_a_Cascaded_Network_for_Simulation\"><\/span>How to Release a Cascaded Network for Simulation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Record the original files, the model generator and version, frequency range, grid, port directions, reference impedances, joins and operations. Sanity-check with a known low-reflection case. If the assembled measurement differs, first check planes, order and repeated hardware, then compare at original sample points before blaming interpolation. For passive blocks check the resulting model as appropriate; for transient use review the required causality and bandwidth assumptions separately. If the cascade will drive a step or eye simulation, use the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/s-parameter-dc-extrapolation\/\">S-parameter DC extrapolation guide<\/a> to check that the combined path has the correct low-frequency limit.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Cascading_S-Parameters_FAQs\"><\/span>Cascading S-Parameters FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>Can I multiply the S21 magnitudes?<\/h3>\n<p>Only as an approximation unless the internal reflection product is zero. Bound the error before making a decision.<\/p>\n<h3>Can two lossy stages have less loss than a scalar estimate suggests?<\/h3>\n<p>Yes. Interface reflection phase can increase or decrease transmission relative to the scalar product. That does not imply a passive assembly creates gain.<\/p>\n<h3>Can I multiply the two raw S matrices?<\/h3>\n<p>No. Use an appropriate connection calculation or a compatible chain representation.<\/p>\n<h3>What if the port references are different?<\/h3>\n<p>Use a method that handles the reference impedances and wave conventions for both full matrices. Do not treat that as a model of unspecified physical hardware.<\/p>\n<h3>Can I cascade files with different frequency grids?<\/h3>\n<p>Only after aligning them with a justified method in their common band. Check independent points where sharp features matter.<\/p>\n<h3>Does agreement in dB prove the model is correct?<\/h3>\n<p>No. Compare the relevant complex transmission and reflection terms at matching planes.<\/p>\n<h3>What if there is a deep null near the conversion?<\/h3>\n<p>Common chain conversions can amplify numerical and measurement errors when forward transmission is tiny. Check the method&#8217;s conditioning and the measured floor.<\/p>\n<h3>When is a two-port model insufficient?<\/h3>\n<p>Use a wider model when coupling, common-mode paths, or additional ports matter and cannot be represented independently with the intended terminations.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Technical_References\"><\/span>Technical References<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/edadownload.software.keysight.com\/eedl\/ads\/2011\/pdf\/rfsysbudget.pdf\" rel=\"nofollow\">Keysight ADS RF System Budget Analysis<\/a> \u2014 cascade of two two-port components.<\/li>\n<li><a href=\"https:\/\/helpfiles.keysight.com\/csg\/e5071c\/measurement\/data_analysis\/equation_editor.htm\" rel=\"nofollow\">Keysight ENA Equation Editor<\/a> \u2014 network parameter representations.<\/li>\n<li><a href=\"https:\/\/scikit-rf.readthedocs.io\/en\/latest\/api\/generated\/skrf.network.connect.html\" rel=\"nofollow\">scikit-rf: Connecting Networks<\/a> \u2014 explicit ports and impedance handling.<\/li>\n<li><a href=\"https:\/\/www.ibis.org\/touchstone_ver2.1\/touchstone_ver2_1.pdf\" rel=\"nofollow\">IBIS Open Forum: Touchstone File Format Specification v2.1<\/a> \u2014 file representations and reference definitions.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Custom_High-Speed_PCBs_With_Stackup_and_Coupon_Review\"><\/span>Custom High-Speed PCBs With Stackup and Coupon Review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Need a custom RF or high-speed PCB? Ask EBest Circuit to review the proposed stackup and test coupon before fabrication. Send the layout or Gerbers, impedance targets, test interfaces, quantity and delivery needs to <a href=\"mailto:sales@bestpcbs.com\">sales@bestpcbs.com<\/a> for a project review and quotation.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.<\/p>\n","protected":false},"author":32827,"featured_media":39234,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[174],"tags":[9214,9458,9460,8862],"class_list":["post-39235","post","type-post","status-publish","format-standard","hentry","category-bestpcb","tag-s-parameters","tag-s-parameter-renormalization","tag-touchstone-file","tag-vna-s21-measurement"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"mingling, gong\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Cascading S-Parameters: When Adding Loss in dB Fails - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta property=\"og:description\" content=\"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-16T18:49:34+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-16T19:23:42+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Cascading S-Parameters: When Adding Loss in dB Fails - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#blogposting\",\"name\":\"Cascading S-Parameters: When Adding Loss in dB Fails - PCB & MCPCB - EBest PCB\",\"headline\":\"Cascading S-Parameters: When Adding Loss in dB Fails\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cascading-s-parameters-feature.jpg\",\"width\":1200,\"height\":600},\"datePublished\":\"2026-11-17T02:49:34+08:00\",\"dateModified\":\"2026-11-17T03:23:42+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#webpage\"},\"articleSection\":\"bestpcb, S Parameters, S-parameter renormalization, Touchstone file, VNA S21 Measurement\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"position\":2,\"name\":\"bestpcb\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#listItem\",\"name\":\"Cascading S-Parameters: When Adding Loss in dB Fails\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#listItem\",\"position\":3,\"name\":\"Cascading S-Parameters: When Adding Loss in dB Fails\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/\",\"name\":\"mingling, gong\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"mingling, gong\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/\",\"name\":\"Cascading S-Parameters: When Adding Loss in dB Fails - PCB & MCPCB - EBest PCB\",\"description\":\"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cascading-s-parameters-feature.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#mainImage\",\"width\":1200,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/cascading-s-parameters\\\/#mainImage\"},\"datePublished\":\"2026-11-17T02:49:34+08:00\",\"dateModified\":\"2026-11-17T03:23:42+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Cascading S-Parameters: When Adding Loss in dB Fails - PCB & MCPCB - EBest PCB","description":"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#blogposting","name":"Cascading S-Parameters: When Adding Loss in dB Fails - PCB & MCPCB - EBest PCB","headline":"Cascading S-Parameters: When Adding Loss in dB Fails","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/cascading-s-parameters-feature.jpg","width":1200,"height":600},"datePublished":"2026-11-17T02:49:34+08:00","dateModified":"2026-11-17T03:23:42+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#webpage"},"articleSection":"bestpcb, S Parameters, S-parameter renormalization, Touchstone file, VNA S21 Measurement"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","position":2,"name":"bestpcb","item":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#listItem","name":"Cascading S-Parameters: When Adding Loss in dB Fails"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#listItem","position":3,"name":"Cascading S-Parameters: When Adding Loss in dB Fails","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/","name":"mingling, gong","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g","width":96,"height":96,"caption":"mingling, gong"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/","name":"Cascading S-Parameters: When Adding Loss in dB Fails - PCB & MCPCB - EBest PCB","description":"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/cascading-s-parameters-feature.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#mainImage","width":1200,"height":600},"primaryImageOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/#mainImage"},"datePublished":"2026-11-17T02:49:34+08:00","dateModified":"2026-11-17T03:23:42+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"Cascading S-Parameters: When Adding Loss in dB Fails - PCB &amp; MCPCB - EBest PCB","og:description":"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-11-16T18:49:34+00:00","article:modified_time":"2026-11-16T19:23:42+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"Cascading S-Parameters: When Adding Loss in dB Fails - PCB &amp; MCPCB - EBest PCB","twitter:description":"Cascade two-port S-parameters without losing mismatch information. See when adding insertion loss fails and verify the complete PCB channel on the bench.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"39235","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2026-11-16 18:49:37","updated":"2026-11-17 00:44:16","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/\" title=\"bestpcb\">bestpcb<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tCascading S-Parameters: When Adding Loss in dB Fails\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog\/"},{"label":"bestpcb","link":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/"},{"label":"Cascading S-Parameters: When Adding Loss in dB Fails","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/cascading-s-parameters\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39235","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/32827"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=39235"}],"version-history":[{"count":2,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39235\/revisions"}],"predecessor-version":[{"id":39244,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39235\/revisions\/39244"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media\/39234"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=39235"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=39235"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=39235"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}