


{"id":39163,"date":"2026-11-16T21:05:35","date_gmt":"2026-11-16T13:05:35","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/?p=39163"},"modified":"2026-11-16T22:15:27","modified_gmt":"2026-11-16T14:15:27","slug":"vna-if-bandwidth","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/","title":{"rendered":"VNA IF Bandwidth: Is Your Filter Stopband Real?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#What_Is_VNA_IF_Bandwidth\" >What Is VNA IF Bandwidth?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_Noise_Floor_Check_Two_Baselines\" >VNA Noise Floor: Check Two Baselines<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_Dynamic_Range_Check_the_Weakest_Part_of_the_Band\" >VNA Dynamic Range: Check the Weakest Part of the Band<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#S21_Measurement_Record_a_Wide_and_a_Narrow_Sweep\" >S21 Measurement: Record a Wide and a Narrow Sweep<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_Averaging_vs_Narrower_IF_Bandwidth\" >VNA Averaging vs. Narrower IF Bandwidth<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_Calibration_Recheck_It_Before_Comparing_Settings\" >VNA Calibration: Recheck It Before Comparing Settings<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_Sweep_Time_Spend_Time_Where_It_Changes_the_Decision\" >VNA Sweep Time: Spend Time Where It Changes the Decision<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#Filter_Stopband_Attenuation_Decide_What_You_Can_Report\" >Filter Stopband Attenuation: Decide What You Can Report<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#VNA_IF_Bandwidth_FAQs\" >VNA IF Bandwidth FAQs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#Technical_References\" >Technical References<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#Custom_RF_PCBs_With_Stackup_and_Test_Coupon_Review\" >Custom RF PCBs With Stackup and Test Coupon Review<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div><p>If a PCB filter&#8217;s S21 flattens in the stopband, <strong>narrow the VNA IF bandwidth and measure the baseline in the same setup<\/strong>. In a receiver limited by white noise, reducing the bandwidth from 1 kHz to 100 Hz should lower the random noise floor by about 10 dB. If a repeatable plateau remains near the fixture&#8217;s isolation baseline, a narrower setting alone will not prove the filter meets its rejection target.<\/p>\n<p>The useful result is not the deepest number the screen displays. It is a reading that can be separated from noise and leakage well enough to decide whether the PCB meets the requirement across the specified band.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-if-bandwidth.jpg\" width=\"1200\" height=\"600\" style=\"display:block;max-width:100%;height:auto\" alt=\"Illustrative two-port vector network analyzer connected to an enclosed RF filter fixture\"><figcaption>Illustration of a two-port test arrangement. Keep the physical setup stable while changing receiver settings.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_VNA_IF_Bandwidth\"><\/span>What Is VNA IF Bandwidth?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>VNA IF bandwidth is the width of the receiver filter used after the RF signal has been translated to an intermediate frequency. It controls how much noise reaches each measurement point. It is not the RF sweep span, the spacing between frequency points, or the physical bandwidth of the filter under test.<\/p>\n<p>For approximately white receiver noise, noise power is proportional to effective bandwidth. The ideal change is 10 log<sub>10<\/sub>(new bandwidth \u00f7 old bandwidth) dB, so a change from 1 kHz to 100 Hz gives \u221210 dB. Keysight documents the trend experimentally for one class of instruments. It does not predict the sweep time or lower a signal leaking coherently around the device.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Noise_Floor_Check_Two_Baselines\"><\/span>VNA Noise Floor: Check Two Baselines<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Separate the receiver-and-cable baseline from leakage through the full fixture. A documented isolation check with the two cable ends independently terminated in appropriate matched loads, with no intended through path, shows what the receiver and external setup report under that condition. A representative isolation witness with the relevant fixture retained can reveal coupling that the separately terminated cables missed.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-baseline-terms.jpg\" width=\"1200\" height=\"540\" style=\"display:block;max-width:100%;height:auto\" alt=\"Two independent VNA ports connected to separate matched loads without a through path\"><figcaption>Independent terminations are useful for the receiver-and-cable check. Removing the fixture means this check does not capture all of its leakage.<\/figcaption><\/figure>\n<p>Match source level, receiver mode, frequency grid and IF bandwidth to the device run. Document where calibration ends and whether the analyzer uses isolation correction. An isolation-corrected baseline is not an independent witness if the same trace was used to derive the correction. Follow instrument instructions for appropriate loads and connections. With the real fixture in use, the isolation witness must preserve the geometry and relevant coupling paths; if it cannot, report that limitation.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Dynamic_Range_Check_the_Weakest_Part_of_the_Band\"><\/span>VNA Dynamic Range: Check the Weakest Part of the Band<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Usable dynamic range is set by the actual setup at the frequencies of interest. Check the separation between the device and a relevant baseline point by point, or at the weakest locations under a justified sampling plan. A single best-case dynamic-range number from the front page of an instrument datasheet can miss an in-band leakage spur or a noisier frequency region.<\/p>\n<p>Higher source power can improve a weak reading only while the board and receiver still behave as intended. If the observed gain begins to fall as you raise the drive, use the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-power-sweep\/\">VNA power sweep guide<\/a> to check whether the board or the receiver is compressing.<\/p>\n<p>A separation in dB is a screening number, not a measurement uncertainty by itself. Coherent leakage can add or cancel, and receiver noise varies from sweep to sweep. Compare repeats including a reference, and apply the project&#8217;s agreed uncertainty and decision rule. If the limit lies within the unverified region, record the measurement limitation instead of assigning a precise stopband value.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"S21_Measurement_Record_a_Wide_and_a_Narrow_Sweep\"><\/span>S21 Measurement: Record a Wide and a Narrow Sweep<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>First record the wider-bandwidth baseline, the device and an appropriate reference response. Repeat at a narrower bandwidth with the same grid, test power, fixture geometry and gain settings. Some analyzers adjust operating ranges automatically; verify and record the actual state. Preserve raw sweeps without smoothing. A baseline that drops while the device feature remains repeatable supports a real response. A device trace that drops with the baseline may still be unresolved.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-stopband-baseline.jpg\" width=\"1200\" height=\"540\" style=\"display:block;max-width:100%;height:auto\" alt=\"Illustrative S21 plot showing a wide-bandwidth floor partly masking the DUT stopband and a lower narrow-bandwidth floor\"><figcaption>Conceptual sketch, not a measurement. Narrowing the receiver bandwidth can separate a DUT response from random noise, but the fixture floor still needs its own check.<\/figcaption><\/figure>\n<p>Keep the cables still between runs. If a repeatable phase or magnitude change tracks cable pose rather than IF bandwidth, use the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-cable-movement\/\">VNA cable movement guide<\/a> to distinguish flex from connector remating. Changing the setting and reconnecting at the same time would obscure which variable caused the difference.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Averaging_vs_Narrower_IF_Bandwidth\"><\/span>VNA Averaging vs. Narrower IF Bandwidth<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Try a narrower IF bandwidth first if the receiver noise is the problem and the sweep budget allows it. Use vector averaging for stable repeated sweeps when you still need better repeatability. Do not substitute trace smoothing for either. Smoothing blends neighboring frequencies and can hide a narrow leak in the stopband.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td><strong>Control<\/strong><\/td>\n<td><strong>What it changes<\/strong><\/td>\n<td><strong>When to use it<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Narrower IF bandwidth<\/td>\n<td>Restricts receiver noise per frequency point; usually takes longer to sweep<\/td>\n<td>Weak transmission with a baseline that falls when bandwidth is reduced<\/td>\n<\/tr>\n<tr>\n<td>Vector averaging<\/td>\n<td>Combines repeated complex samples; coherent leakage can remain<\/td>\n<td>A stable setup where repeated sweeps still show uncorrelated noise<\/td>\n<\/tr>\n<tr>\n<td>Trace smoothing<\/td>\n<td>Combines neighboring frequency points in the displayed response<\/td>\n<td>Only for a labeled overview if appropriate; use raw resolution for a narrow-feature limit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>For ten independent, equal-weight samples of zero-mean noise, the averaged noise power falls by a factor of ten, or 10 dB. The actual instrument averaging algorithm, settling and drift determine whether its \u201c10\u201d setting behaves that way. Time the completed result, not only the first visible sweep.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Calibration_Recheck_It_Before_Comparing_Settings\"><\/span>VNA Calibration: Recheck It Before Comparing Settings<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Set the measurement conditions first where practical, then calibrate to the required reference planes. After an IF bandwidth change, follow the procedure for the specific analyzer. In one Keysight M9485A mode, changing it after calibration can trigger a C-delta status indicating uncertain correction accuracy. Do not assume all instruments handle that change the same way.<\/p>\n<p>Check a suitable reference after the change and recalibrate if the method requires it. Save the correction state, calibration plane, frequency grid, source level and time. If a new calibration changes the reference itself beyond your repeatability allowance, fix or explain that discrepancy before claiming the bandwidth experiment isolated noise.<\/p>\n<p>When comparing a 50 \u03a9 measurement with a 75 \u03a9 requirement, settle the reference basis before interpreting a changed trace. The <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/s-parameter-renormalization\/\">S-parameter renormalization guide<\/a> separates mathematical conversion from moving the calibration plane or changing the test hardware.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_Sweep_Time_Spend_Time_Where_It_Changes_the_Decision\"><\/span>VNA Sweep Time: Spend Time Where It Changes the Decision<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The narrowest setting is not automatically best. Choose the widest validated IF bandwidth that separates the signal from the floor and meets the repeatability needed for your decision. Measure the actual sweep time. Instrument overhead, source changes and filter implementation mean a tenfold reduction in IF bandwidth does not imply exactly ten times the total duration.<\/p>\n<p>On analyzers that support segment sweeps, narrow the receiver bandwidth in the stopband while keeping a suitable frequency grid near narrow features. Keep the rest of the band as fast as the test allows, but verify the full production recipe against a reference. Changing segment boundaries or omitting points to save time must not skip a frequency region covered by the requirement.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Filter_Stopband_Attenuation_Decide_What_You_Can_Report\"><\/span>Filter Stopband Attenuation: Decide What You Can Report<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use the worksheet below at a defined frequency where a result may be limited by the setup. Enter the absolute S21 display levels at the same conditions and subtract the baseline from the DUT reading. Then decide whether you have sufficient independent evidence for a numerical result. These are teaching numbers; they are not PCB measurements or instrument specifications.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td><strong>Example condition<\/strong><\/td>\n<td><strong>DUT \/ baseline, dB<\/strong><\/td>\n<td><strong>Observed separation<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1 kHz versus independently terminated baseline<\/td>\n<td>\u221275 \/ \u221282<\/td>\n<td>7 dB<\/td>\n<\/tr>\n<tr>\n<td>100 Hz versus independently terminated baseline<\/td>\n<td>\u221277 \/ \u221292<\/td>\n<td>15 dB<\/td>\n<\/tr>\n<tr>\n<td>100 Hz versus separate fixture isolation witness<\/td>\n<td>\u221277 \/ \u221286<\/td>\n<td>9 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><strong>How to use the third row:<\/strong> subtract \u221286 dB from \u221277 dB to get 9 dB. If the contract calls for S21 no higher than \u221270 dB, the indicated value is 7 dB below that boundary. Neither 7 dB nor 9 dB is the error bound. Check the repeatability, leakage behavior and decision rule before claiming pass. If the isolation witness limits confidence, improve or characterize the fixture rather than reporting extra decimal places.<\/p>\n<p>For a filter stopband, verify frequency coverage, weakest rejection and comparison to the isolation witness. For adjacent PCB paths, retain the relevant routing, launches and return geometry when checking unwanted coupling. For rapid production screening, validate the fastest acceptable setup against a suitable reference and keep a path for retesting borderline samples. Each use case makes a different claim; do not transfer the filter&#8217;s measured baseline to a different fixture or board.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"VNA_IF_Bandwidth_FAQs\"><\/span>VNA IF Bandwidth FAQs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>Does IF bandwidth set the spacing between VNA points?<\/h3>\n<p>No. Frequency point spacing describes where the response is sampled. IF bandwidth changes the receiver bandwidth at those points. You still need enough points to resolve a narrow feature.<\/p>\n<h3>Is averaging dB values the same as vector averaging?<\/h3>\n<p>No. Vector averaging works on complex measurements before display; averaging the displayed decibel magnitudes is a different calculation. Use the analyzer&#8217;s documented mode and save what it does.<\/p>\n<h3>Why does a stable plateau stay at the same level?<\/h3>\n<p>It may be real transmission, or it may be repeatable coupling through the setup. Compare the plateau with a suitable isolation witness and change one setup condition at a time.<\/p>\n<h3>Can a peak above the baseline still be measurement error?<\/h3>\n<p>Yes. A coherent leakage path can add to or cancel real transmission. A repeatable separation supports further measurement, but the setup and the decision rule still determine what can be claimed.<\/p>\n<h3>Will changing source power give me more usable range?<\/h3>\n<p>It may help in a linear setup limited by receiver noise, but not if the source-to-receiver leakage rises with it or the device enters compression. Stay within equipment and device limits and repeat the baselines.<\/p>\n<h3>Can I use a lower IF bandwidth to remove fixture mismatch?<\/h3>\n<p>No. It does not correct the impedance discontinuity. Verify the calibration references and treat fixture mismatch separately from receiver noise.<\/p>\n<h3>Is the strongest stopband marker enough for a qualification report?<\/h3>\n<p>No. Report the weakest relevant rejection across the specified band and any regions where the setup could not establish the requested claim. Keep the original traces and settings.<\/p>\n<h3>Should I quote stopband rejection as positive or negative decibels?<\/h3>\n<p>Label the convention. An S21 reading of \u221270 dB corresponds to 70 dB attenuation using the same reference and transmission definition. The direction of the acceptance inequality changes with the convention.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Technical_References\"><\/span>Technical References<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/helpfiles.keysight.com\/csg\/m9485a\/s2_opt\/trce_noise.htm\" rel=\"nofollow\">Keysight M9485A: Trace Noise<\/a>, IF bandwidth, averaging, smoothing and calibration-state example.<\/li>\n<li><a href=\"https:\/\/www.keysight.com\/in\/en\/assets\/7018-06837\/application-notes\/5980-2778.pdf\" rel=\"nofollow\">Keysight application note 5980-2778<\/a>, Figure 3 receiver-noise measurements versus IF bandwidth.<\/li>\n<li><a href=\"https:\/\/helpfiles.keysight.com\/csg\/m9485a\/s2_opt\/fast_swp.htm\" rel=\"nofollow\">Keysight M9485A: Fast Sweep Speed<\/a>, balancing sweep time with noise and dynamic range.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Custom_RF_PCBs_With_Stackup_and_Test_Coupon_Review\"><\/span>Custom RF PCBs With Stackup and Test Coupon Review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Before releasing an RF PCB order, ask EBest Circuit to review the proposed stackup and test coupon requirements together. State the band, target impedances and RF features that must be reproduced so the quote can distinguish board fabrication evidence from the device-level test you plan to run.<\/p>\n<p>For an RF PCB fabrication quote, send your Gerber or ODB++ data, drawing revision, stackup, quantity and test requirements to <a href=\"mailto:sales@bestpcbs.com\">sales@bestpcbs.com<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.<\/p>\n","protected":false},"author":32827,"featured_media":39160,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[174],"tags":[9457,9456,9454,9455],"class_list":["post-39163","post","type-post","status-publish","format-standard","hentry","category-bestpcb","tag-filter-stopband","tag-rf-pcb-measurement","tag-vna-if-bandwidth","tag-vna-noise-floor"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"mingling, gong\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta property=\"og:description\" content=\"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-16T13:05:35+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-16T14:15:27+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB &amp; MCPCB - EBest PCB\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#blogposting\",\"name\":\"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB & MCPCB - EBest PCB\",\"headline\":\"VNA IF Bandwidth: Is Your Filter Stopband Real?\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-if-bandwidth.jpg\",\"width\":1200,\"height\":600},\"datePublished\":\"2026-11-16T21:05:35+08:00\",\"dateModified\":\"2026-11-16T22:15:27+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#webpage\"},\"articleSection\":\"bestpcb, filter stopband, RF PCB measurement, VNA IF bandwidth, VNA noise floor\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"position\":2,\"name\":\"bestpcb\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#listItem\",\"name\":\"VNA IF Bandwidth: Is Your Filter Stopband Real?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#listItem\",\"position\":3,\"name\":\"VNA IF Bandwidth: Is Your Filter Stopband Real?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/\",\"name\":\"mingling, gong\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"mingling, gong\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/\",\"name\":\"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB & MCPCB - EBest PCB\",\"description\":\"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/vna-if-bandwidth.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#mainImage\",\"width\":1200,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/vna-if-bandwidth\\\/#mainImage\"},\"datePublished\":\"2026-11-16T21:05:35+08:00\",\"dateModified\":\"2026-11-16T22:15:27+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB & MCPCB - EBest PCB","description":"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#blogposting","name":"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB & MCPCB - EBest PCB","headline":"VNA IF Bandwidth: Is Your Filter Stopband Real?","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-if-bandwidth.jpg","width":1200,"height":600},"datePublished":"2026-11-16T21:05:35+08:00","dateModified":"2026-11-16T22:15:27+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#webpage"},"articleSection":"bestpcb, filter stopband, RF PCB measurement, VNA IF bandwidth, VNA noise floor"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","position":2,"name":"bestpcb","item":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#listItem","name":"VNA IF Bandwidth: Is Your Filter Stopband Real?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#listItem","position":3,"name":"VNA IF Bandwidth: Is Your Filter Stopband Real?","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/","name":"mingling, gong","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g","width":96,"height":96,"caption":"mingling, gong"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/","name":"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB & MCPCB - EBest PCB","description":"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/vna-if-bandwidth.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#mainImage","width":1200,"height":600},"primaryImageOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/#mainImage"},"datePublished":"2026-11-16T21:05:35+08:00","dateModified":"2026-11-16T22:15:27+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB &amp; MCPCB - EBest PCB","og:description":"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-11-16T13:05:35+00:00","article:modified_time":"2026-11-16T14:15:27+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"VNA IF Bandwidth: Is Your Filter Stopband Real? - PCB &amp; MCPCB - EBest PCB","twitter:description":"Use two VNA IF bandwidths and a fixture isolation check to tell real PCB filter attenuation from receiver noise before reporting your stopband.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"39163","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2026-11-16 13:05:42","updated":"2026-11-16 14:59:25","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/\" title=\"bestpcb\">bestpcb<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tVNA IF Bandwidth: Is Your Filter Stopband Real?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog\/"},{"label":"bestpcb","link":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/"},{"label":"VNA IF Bandwidth: Is Your Filter Stopband Real?","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/vna-if-bandwidth\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/32827"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=39163"}],"version-history":[{"count":3,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39163\/revisions"}],"predecessor-version":[{"id":39177,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/39163\/revisions\/39177"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media\/39160"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=39163"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=39163"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=39163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}