


{"id":38774,"date":"2026-11-10T19:43:06","date_gmt":"2026-11-10T11:43:06","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/"},"modified":"2026-11-10T19:43:06","modified_gmt":"2026-11-10T11:43:06","slug":"can-fd-split-termination-resistance-waveform","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/","title":{"rendered":"CAN FD Termination Guide: Check Resistance and Ringing"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_fd_termination\" >can fd termination<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_termination_resistor_location\" >can bus termination resistor location<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_termination_resistor_value\" >can bus termination resistor value<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_termination_resistance\" >can bus termination resistance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_fd_split_termination\" >can fd split termination<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_split_termination_capacitor_value\" >can bus split termination capacitor value<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_signal_reflections\" >can bus signal reflections<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#can_bus_oscilloscope_waveform\" >can bus oscilloscope waveform<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#FAQ\" >FAQ<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#Sources\" >Sources<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#Project_Review\" >Project Review<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div><p>Start with two matched end terminations on a conventional linear CAN FD bus. With the bus safely de-energized and the applicable network isolated, about 60 \u03a9 across CANH and CANL is a useful check for two nominal 120 \u03a9 ends in parallel. It cannot tell you where those resistors are or whether a long stub is causing ringing. Check the physical ends next, then measure the differential and common-mode waveforms separately.<\/p>\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/can-fd-termination.jpg\" alt=\"CAN controller PCB beside a twisted pair connected to a terminal block\" width=\"1200\" height=\"675\" style=\"max-width:100%;height:auto;\"><figcaption>Illustrative rendering of a CAN interface, not a validated circuit or a compliance result.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"can_fd_termination\"><\/span>can fd termination<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Termination matches the end of a transmission line to reduce reflected edges. The physical ends of the trunk are the ends that matter, not the two nodes with the lowest software addresses. Confirm the bus topology and cable impedance before applying the conventional two-end model. An engineered non-linear network needs its own analysis rather than extra resistors added by trial and error.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_termination_resistor_location\"><\/span>can bus termination resistor location<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Walk the actual harness and mark both ends, every branch and any switchable termination. A termination at an intermediate node can still contribute the expected DC resistance while leaving a length of cable beyond it unterminated. In a hypothetical controller and sensor harness, a service node is plugged in midway and accidentally has termination enabled. If the far end is also missing its resistor, the meter can still show 60 \u03a9, yet the far end remains electrically open to an arriving edge.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_termination_resistor_value\"><\/span>can bus termination resistor value<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For the conventional 120 \u03a9 network, use a nominal 120 \u03a9 differential termination at each physical end. In a split arrangement, two matched nominal 60 \u03a9 resistors form one 120 \u03a9 end. The midpoint capacitor adds a path for common-mode AC energy without adding a DC resistor across the pair.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td><strong>Parameter<\/strong><\/td>\n<td><strong>What to verify<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Nominal end resistance<\/td>\n<td>120 \u03a9 for the conventional cable<\/td>\n<\/tr>\n<tr>\n<td>Split pair<\/td>\n<td>Two matched 60 \u03a9 resistors per end<\/td>\n<\/tr>\n<tr>\n<td>Midpoint capacitor<\/td>\n<td>Value, rating and return for this design<\/td>\n<\/tr>\n<tr>\n<td>Resistor power<\/td>\n<td>Check fault voltage, duration and part rating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_termination_resistance\"><\/span>can bus termination resistance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>With power removed and the network in the intended measurement state, compare the reading with the expected parallel combination. Two 120 \u03a9 resistors give 60 \u03a9, one gives 120 \u03a9 and three give 40 \u03a9 in the ideal calculation. Treat those as clues, not acceptance limits: tolerances, other DC paths, internal switches and the connected harness can change the reading. Segment the harness as permitted and identify each termination before concluding that a board needs rework.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"can_fd_split_termination\"><\/span>can fd split termination<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Use a single resistor when the end is correctly matched and the common-mode behavior meets requirements. Consider split termination when the end match is right but common-mode disturbance remains an issue. It adds parts and a return path to review. It does not move a termination to the right place or shorten a stub.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td><strong>Option<\/strong><\/td>\n<td><strong>Use when<\/strong><\/td>\n<td><strong>Verify<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Single resistor<\/td>\n<td>End match and emissions are acceptable<\/td>\n<td>Value and physical location<\/td>\n<\/tr>\n<tr>\n<td>Split pair plus capacitor<\/td>\n<td>Common-mode improvement is needed<\/td>\n<td>Matching, return and EMC result<\/td>\n<\/tr>\n<tr>\n<td>Topology correction<\/td>\n<td>There is an incorrect end or long stub<\/td>\n<td>Reflection at the affected receiver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_split_termination_capacitor_value\"><\/span>can bus split termination capacitor value<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Choose the starting value from the transceiver and system guidance. NXP&#8217;s FS2400 example lists 4.7 nF as a nominal option, not a universal requirement. In a simplified common-mode model, the two 60 \u03a9 branches act in parallel, so the effective resistance is 30 \u03a9. Together with 4.7 nF that gives about 1.13 MHz for the ideal RC corner. Cable and return impedances, parasitics and other components change the real response. That number is not a CAN FD data-rate limit and cannot predict compliance.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_signal_reflections\"><\/span>can bus signal reflections<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If errors cluster after edges or at the faster data phase, look for timing and topology clues before changing the capacitor. On the hypothetical service harness, restore termination at the physical far end and disable the misplaced branch termination. Repeat the same capture. If ringing persists at one branch, compare the branch connection and length against the approved network design. A changing common-mode signal alone is not proof of a differential reflection.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"can_bus_oscilloscope_waveform\"><\/span>can bus oscilloscope waveform<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Measure CANH minus CANL for differential behavior and, with a suitable referenced and matched setup, use their average to inspect common mode. Follow the instrument and equipment safety instructions and avoid grounding a floating bus through the probe. Compare the same receiver, harness, traffic and supply conditions before and after changes. Release only when the correct end map, resistance, waveform or timing limits, error behavior and any required system EMC tests meet the project plan.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/can-bus-oscilloscope.jpg\" alt=\"CAN evaluation board and twisted pair on a bench near an oscilloscope\" width=\"1200\" height=\"675\" style=\"max-width:100%;height:auto;\" loading=\"lazy\"><figcaption>Illustrative rendering of a scope bench. Use calibrated measurements and the actual receiver location for comparison.<\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3>Why do I see 60 \u03a9 but still get errors?<\/h3>\n<p>The meter cannot locate the resistors or see stubs, receiver timing or interference. Confirm the end map, then capture signals at the failing receiver.<\/p>\n<h3>Should every node include an enabled 120 \u03a9 resistor?<\/h3>\n<p>No. In a conventional linear trunk, enable termination at the two physical ends. An optional resistor footprint on an intermediate node can remain unpopulated or disabled.<\/p>\n<h3>Does split termination change the nominal differential DC resistance?<\/h3>\n<p>Not when each end still sums to the specified end resistance and the midpoint capacitor has no DC conduction path under the measurement conditions.<\/p>\n<h3>Can I choose capacitor size by looking at the data rate?<\/h3>\n<p>Not alone. The midpoint network targets common-mode behavior. Start from the device guidance and verify it against the actual noise and immunity requirements.<\/p>\n<h3>Does unplugging a node always leave the resistance unchanged?<\/h3>\n<p>No. The unplugged module may contain an end resistor or active termination. Identify what was removed and re-evaluate the expected reading for that configuration.<\/p>\n<h3>Should I fit a common-mode choke before changing the layout?<\/h3>\n<p>Check the failure mechanism first. A choke may help a specific emissions or immunity issue, but it will not correct an unterminated cable end or an overly long stub.<\/p>\n<h3>Is a clean waveform at the transmitting node enough?<\/h3>\n<p>No. Check the receiver that sees errors and other electrically distinct points. A reflection that is mild at one location may be significant at another.<\/p>\n<h3>What if the conventional 60 \u03a9 rule does not fit this network?<\/h3>\n<p>Use the network designer&#8217;s topology and expected measurement state. Switched termination, active networks and branches require interpretation beyond the simple parallel model.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Sources\"><\/span>Sources<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.nxp.com\/docs\/en\/application-note\/AN14183.pdf\">NXP AN14183: CAN components example<\/a>; <a href=\"https:\/\/www.ti.com\/lit\/ug\/sllu234a\/sllu234a.pdf\">TI: TCAN evaluation module termination options<\/a>; <a href=\"https:\/\/www.ti.com\/document-viewer\/lit\/html\/SSZTAM0\">TI: split termination and common-mode behavior<\/a>.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Project_Review\"><\/span>Project Review<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For a PCB fabrication discussion, send Best Technology the board stackup, connector region and proposed termination footprints at <a href=\"mailto:sales@bestpcbs.com\">sales@bestpcbs.com<\/a>. If the protocol itself is still being selected, see the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/10\/can-bus-vs-lin-bus\/\">CAN bus vs LIN bus guide<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.<\/p>\n","protected":false},"author":32827,"featured_media":38772,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[174],"tags":[9295,689,8099,9296],"class_list":["post-38774","post","type-post","status-publish","format-standard","hentry","category-bestpcb","tag-can-fd","tag-pcb-layout","tag-signal-integrity","tag-split-termination"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"mingling, gong\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CAN FD Termination Guide: Check Resistance and Ringing\" \/>\n\t\t<meta property=\"og:description\" content=\"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-10T11:43:06+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-10T11:43:06+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CAN FD Termination Guide: Check Resistance and Ringing\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#blogposting\",\"name\":\"CAN FD Termination Guide: Check Resistance and Ringing\",\"headline\":\"CAN FD Termination Guide: Check Resistance and Ringing\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/can-fd-termination.jpg\",\"width\":1200,\"height\":675},\"datePublished\":\"2026-11-10T19:43:06+08:00\",\"dateModified\":\"2026-11-10T19:43:06+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#webpage\"},\"articleSection\":\"bestpcb, CAN FD, PCB Layout, Signal Integrity, Split Termination\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"position\":2,\"name\":\"bestpcb\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#listItem\",\"name\":\"CAN FD Termination Guide: Check Resistance and Ringing\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#listItem\",\"position\":3,\"name\":\"CAN FD Termination Guide: Check Resistance and Ringing\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/bestpcb\\\/#listItem\",\"name\":\"bestpcb\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/\",\"name\":\"mingling, gong\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"mingling, gong\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/\",\"name\":\"CAN FD Termination Guide: Check Resistance and Ringing\",\"description\":\"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/gong588\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/can-fd-termination.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#mainImage\",\"width\":1200,\"height\":675},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/11\\\/can-fd-split-termination-resistance-waveform\\\/#mainImage\"},\"datePublished\":\"2026-11-10T19:43:06+08:00\",\"dateModified\":\"2026-11-10T19:43:06+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"CAN FD Termination Guide: Check Resistance and Ringing","description":"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#blogposting","name":"CAN FD Termination Guide: Check Resistance and Ringing","headline":"CAN FD Termination Guide: Check Resistance and Ringing","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/can-fd-termination.jpg","width":1200,"height":675},"datePublished":"2026-11-10T19:43:06+08:00","dateModified":"2026-11-10T19:43:06+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#webpage"},"articleSection":"bestpcb, CAN FD, PCB Layout, Signal Integrity, Split Termination"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","position":2,"name":"bestpcb","item":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#listItem","name":"CAN FD Termination Guide: Check Resistance and Ringing"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#listItem","position":3,"name":"CAN FD Termination Guide: Check Resistance and Ringing","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/#listItem","name":"bestpcb"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/","name":"mingling, gong","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/37717913504b7ea1df97ec73d58a7bcc?s=96&d=mm&r=g","width":96,"height":96,"caption":"mingling, gong"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/","name":"CAN FD Termination Guide: Check Resistance and Ringing","description":"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/gong588\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/11\/can-fd-termination.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#mainImage","width":1200,"height":675},"primaryImageOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/#mainImage"},"datePublished":"2026-11-10T19:43:06+08:00","dateModified":"2026-11-10T19:43:06+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"CAN FD Termination Guide: Check Resistance and Ringing","og:description":"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-11-10T11:43:06+00:00","article:modified_time":"2026-11-10T11:43:06+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"CAN FD Termination Guide: Check Resistance and Ringing","twitter:description":"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"38774","title":"CAN FD Termination Guide: Check Resistance and Ringing","description":"Compare single and split CAN FD termination. Use the power-off resistance and two scope views to find missing ends, stubs, or common-mode noise.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":null,"created":"2026-11-10 11:43:07","updated":"2026-11-10 11:48:31","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/\" title=\"bestpcb\">bestpcb<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tCAN FD Termination Guide: Check Resistance and Ringing\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog\/"},{"label":"bestpcb","link":"https:\/\/www.bestpcbs.com\/blog\/category\/bestpcb\/"},{"label":"CAN FD Termination Guide: Check Resistance and Ringing","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/11\/can-fd-split-termination-resistance-waveform\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/38774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/32827"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=38774"}],"version-history":[{"count":0,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/38774\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media\/38772"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=38774"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=38774"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=38774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}