


{"id":34995,"date":"2026-09-02T18:24:11","date_gmt":"2026-09-02T10:24:11","guid":{"rendered":"https:\/\/www.bestpcbs.com\/blog\/?p=34995"},"modified":"2026-09-02T18:24:13","modified_gmt":"2026-09-02T10:24:13","slug":"transmission-line-termination-techniques","status":"publish","type":"post","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/","title":{"rendered":"What Are the Main Transmission Line Termination Techniques?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-wrap-left counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#What_Is_Transmission_Line_Termination_in_PCB_Design\" >What Is Transmission Line Termination in PCB Design?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#When_Does_a_PCB_Trace_Need_Termination\" >When Does a PCB Trace Need Termination?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Do_the_Main_Transmission_Line_Termination_Techniques_Compare\" >How Do the Main Transmission Line Termination Techniques Compare?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Does_Series_Termination_Work\" >How Does Series Termination Work?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Does_Parallel_Termination_Work\" >How Does Parallel Termination Work?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#When_Should_You_Use_Thevenin_Termination\" >When Should You Use Thevenin Termination?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Does_AC_Termination_Work\" >How Does AC Termination Work?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Is_Termination_Different_for_Differential_Pairs\" >How Is Termination Different for Differential Pairs?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Do_You_Calculate_Termination_Resistor_Values\" >How Do You Calculate Termination Resistor Values?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#Where_Should_Termination_Resistors_Be_Placed\" >Where Should Termination Resistors Be Placed?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Do_Controlled_Impedance_and_PCB_Manufacturing_Affect_Termination\" >How Do Controlled Impedance and PCB Manufacturing Affect Termination?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#What_Are_the_Most_Common_Termination_Mistakes\" >What Are the Most Common Termination Mistakes?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#How_Do_You_Choose_the_Right_Transmission_Line_Termination_Technique\" >How Do You Choose the Right Transmission Line Termination Technique?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#FAQs_About_Transmission_Line_Termination\" >FAQs About Transmission Line Termination<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<div class=\"yzp-no-index\"><\/div>\n<style>.post-34995 > h1._title{word-break:normal!important;overflow-wrap:normal!important}.post-34995 > h1._title,#tlterm051 h2{hyphens:none!important;white-space:normal!important}#tlterm051 h2{border-top:0!important;border-right:0!important;border-bottom:0!important}#tlterm051 .formula{font-family:inherit!important;font-size:inherit!important;white-space:nowrap}#tlterm051 p,#tlterm051 li{text-align:left!important}<\/style>\n<div id=\"tlterm051\" style=\"width:100%;max-width:100%;box-sizing:border-box;word-break:normal;overflow-wrap:normal;\">\n<p class=\"lead\"><strong>The main <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/\">transmission line termination techniques<\/a> in PCB design are series, parallel, Thevenin, and AC termination.<\/strong> Series termination matches the source; the other three place a terminating network at the load. The choice depends on where reflections occur, how much current the driver can supply, and how quickly the receiver must reach a valid logic level.<\/p>\n<p>A low clock frequency does not rule out the need for termination. A fast edge can reflect along a long trace before the voltage settles, while a short trace may work without a discrete resistor. Compare the signal&#8217;s fastest edge with the route delay, then check whether the receiver stays within its voltage and timing limits under the expected operating conditions.<\/p><figure style=\"width:100%;max-width:600px;margin:32px auto;box-sizing:border-box;\"><img decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/09\/termination-techniques-overview-v2.jpg\" width=\"600\" height=\"501\" alt=\"Transmission line termination techniques, series at the source and parallel, Thevenin, or AC at the load.\" style=\"display:block;width:100%;max-width:600px;height:auto;margin:0 auto;\" loading=\"lazy\"><\/figure><h2 id=\"termination-basics\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"What_Is_Transmission_Line_Termination_in_PCB_Design\"><\/span>What Is Transmission Line Termination in PCB Design?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Termination controls reflections by changing the impedance at a transmission line&#8217;s source or load.<\/strong> A PCB trace and its return path have a characteristic impedance, Z<sub>0<\/sub>. When a traveling edge reaches a different impedance, part of the voltage wave returns along the trace. Repeated reflections can cause ringing, overshoot, or a second crossing of a clock input&#8217;s threshold.<\/p>\n<p>For an ideal resistive load, the reflection coefficient is:<\/p>\n<p class=\"formula\" style=\"font-family:Cambria,Georgia,serif;font-size:22px;font-weight:700;margin:22px 0;background:none;\">\u0393<sub>L<\/sub> = (Z<sub>L<\/sub> \u2212 Z<sub>0<\/sub>) \/ (Z<sub>L<\/sub> + Z<sub>0<\/sub>)<\/p>\n<p>A matched load gives \u0393<sub>L<\/sub> = 0. An open circuit gives +1, producing a reflected voltage of the same polarity; a short circuit gives \u22121, producing the opposite polarity. These are simplified limits. Receiver capacitance, package inductance, vias, and connectors make the real response frequency-dependent.<\/p>\n<p>A load terminator absorbs the wave when it reaches the receiver. A source terminator absorbs the reflection when it returns to the driver. Both can control ringing, but the voltage seen along the trace differs between them.<\/p><h2 id=\"when-needed\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"When_Does_a_PCB_Trace_Need_Termination\"><\/span>When Does a PCB Trace Need Termination?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Analyze termination when the route delay is significant relative to the fastest rise or fall time.<\/strong> Clock frequency does not describe edge speed: a 10 MHz signal can still have subnanosecond transitions. Obtain the edge rate under the intended drive strength and loading, then estimate the complete source-to-load delay.<\/p>\n<p>For example, a 100 mm route with an assumed propagation delay of 6 ps\/mm has a one-way delay of 0.6 ns and a round-trip delay of 1.2 ns. With a 1 ns edge, the reflection takes long enough to affect the transition. With a 10 ns edge, the same route is electrically much shorter. The assumed 6 ps\/mm is not a material specification; calculate the delay from the actual stackup.<\/p>\n<p>Check three things before adding a resistor:<\/p>\n<ul><li><strong>Interface requirements:<\/strong> inspect the transmitter and receiver documentation for internal termination, permitted networks, and drive settings. An external resistor may be unnecessary or harmful if matching is already on-chip.<\/li>\n<li><strong>Route topology:<\/strong> identify every receiver, connector, and branch. A source-terminated point-to-point result does not establish that a multi-drop bus will settle correctly.<\/li>\n<li><strong>Receiver margin:<\/strong> compare simulated threshold crossings and settling with the sampling window. For a clock, a second threshold crossing can matter even when the final voltage is correct.<\/li><\/ul><h2 id=\"techniques-compared\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Do_the_Main_Transmission_Line_Termination_Techniques_Compare\"><\/span>How Do the Main Transmission Line Termination Techniques Compare?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>The main trade-off among <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/\">transmission line termination techniques<\/a> is between source matching and load matching.<\/strong> Series termination adds little DC load at a high-impedance receiver. The load-end networks differ in their current demand, bias, and response to repeated transitions.<\/p>\n<div class=\"table-wrap\" style=\"width:100%;max-width:100%;margin:26px 0 30px;box-sizing:border-box;\"><table style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border:1px solid #000;font:inherit;color:inherit;background:transparent;\"><thead><tr><th scope=\"col\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Technique<\/th><th scope=\"col\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Matching action<\/th><th scope=\"col\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Selection condition<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Series<\/th><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Matches the source to absorb the returning wave.<\/td><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">One-way point-to-point route with a high-impedance receiver.<\/td><\/tr>\n<tr><th scope=\"row\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Parallel<\/th><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Absorbs the arriving wave at the load.<\/td><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Load-end matching is needed and the driver supports the DC load.<\/td><\/tr>\n<tr><th scope=\"row\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">Thevenin<\/th><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Provides load matching at a chosen bias voltage.<\/td><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">The interface needs both a terminating resistance and a defined bias.<\/td><\/tr>\n<tr><th scope=\"row\" style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;font-weight:700;\">AC<\/th><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Provides load matching during a limited transient interval.<\/td><td style=\"border:1px solid #000;padding:9px 7px;vertical-align:top;text-align:left;font:inherit;\">Continuous DC loading is undesirable and the signal pattern suits the RC network.<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>A one-way CMOS clock with one receiver is often a good starting point for series termination. If the interface specifies a load-end network, use that circuit as the starting point instead. Differential signaling describes the interconnect mode, not a fifth passive network; its termination follows the receiver and bus specification.<\/p><h2 id=\"series\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Does_Series_Termination_Work\"><\/span>How Does Series Termination Work?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A series resistor combines with the driver&#8217;s output impedance to match Z<sub>0<\/sub> at the source.<\/strong> Place it between the output pin and the main trace, with as little intervening copper as practical. The starting relationship is R<sub>S<\/sub> + Z<sub>driver<\/sub> \u2248 Z<sub>0<\/sub>.<\/p>\n<p>In an ideal matched-source line with a high-impedance far end, the driver launches half of its open-circuit step voltage. At the far end, the positive reflection adds to the incident wave, so the receiver reaches the full step on the <strong>first arrival, after one one-way delay<\/strong>. The reflected wave then returns to the matched source and is absorbed. The receiver does not inherently have to wait for a round trip to reach the full level.<\/p>\n<p>An input partway along a source-terminated trace sees the reduced step first and the returning reflection later. The intermediate voltage may sit near its switching threshold. This is why series termination works best with a single receiver at the far end, although receiver capacitance and package effects still need to be checked.<\/p>\n<p>Series termination draws little steady-state current into a high-impedance load. Too much resistance can slow the edge and reduce timing margin. Check rising and falling transitions separately: the driver&#8217;s pull-up and pull-down impedances may differ. Analog Devices&#8217; explanation of <a href=\"https:\/\/www.analog.com\/en\/resources\/technical-articles\/interfacing-highspeed-signals.html\">high-speed signal interfacing<\/a> describes how the waves travel between the source and load.<\/p><h2 id=\"parallel\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Does_Parallel_Termination_Work\"><\/span>How Does Parallel Termination Work?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Parallel termination places a resistor at the receiver or physical bus end so the incident wave sees a matched load.<\/strong> For a simple single-ended line, begin with R<sub>T<\/sub> \u2248 Z<sub>0<\/sub>, connected to the reference required by the interface.<\/p>\n<p>With a matched resistor, the arriving wave produces little reflection at the load. Keep the copper between the termination node and receiver short; any trace beyond the terminator is still unterminated. The connection to the reference also needs to be short, because its inductance weakens the match at fast edges.<\/p>\n<p>The main cost is DC loading. A resistor to ground draws current in the high state; a resistor to the supply loads the low state. Calculate the actual loaded output voltage as well as resistor power. For an ideal 3.3 V source with 18 \u03a9 output resistance driving 50 \u03a9 to ground, the steady-state load voltage is only 3.3 \u00d7 50 \/ 68 \u2248 2.43 V, and the current is about 48.5 mA. Those assumed values illustrate why a correct impedance can still give an invalid logic level or excessive driver current.<\/p>\n<p>Check the device&#8217;s output characteristics rather than relying on this simple resistive model. Even a smooth transition is unusable if the high level falls below V<sub>IH<\/sub> or the low level rises above V<sub>IL<\/sub>.<\/p><h2 id=\"thevenin\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"When_Should_You_Use_Thevenin_Termination\"><\/span>When Should You Use Thevenin Termination?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Use Thevenin termination when the interface needs load-end matching to a defined bias voltage.<\/strong> A resistor R<sub>1<\/sub> connects the signal to V<sub>CC<\/sub>, and R<sub>2<\/sub> connects it to ground. With low-impedance supply references, their parallel combination sets the terminating resistance:<\/p>\n<p class=\"formula\" style=\"font-family:Cambria,Georgia,serif;font-size:22px;font-weight:700;margin:22px 0;background:none;\">R<sub>eq<\/sub> = R<sub>1<\/sub>R<sub>2<\/sub> \/ (R<sub>1<\/sub> + R<sub>2<\/sub>)<\/p>\n<p class=\"formula\" style=\"font-family:Cambria,Georgia,serif;font-size:22px;font-weight:700;margin:22px 0;background:none;\">V<sub>T<\/sub> = V<sub>CC<\/sub> \u00d7 R<sub>2<\/sub> \/ (R<sub>1<\/sub> + R<sub>2<\/sub>)<\/p>\n<p>For example, two 100 \u03a9 resistors provide 50 \u03a9 equivalent resistance and a 1.65 V unloaded bias from a 3.3 V supply. The undriven divider draws 16.5 mA. Driver current and resistor dissipation change when the signal is actively held high or low, so this is not the complete power budget.<\/p>\n<p>Check the bias voltage as carefully as the resistance. A midpoint bias may leave the receiver at an invalid level while the line is idle or undriven. Resistor tolerance and reference noise affect both the bias and the match. Place both resistors at the load end, then check the high, low, and idle voltages against the receiver limits.<\/p><h2 id=\"ac\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Does_AC_Termination_Work\"><\/span>How Does AC Termination Work?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>AC termination uses a series resistor-capacitor branch from the load to its reference.<\/strong> During a fast transition, the capacitor lets transient current flow through the resistor. After the capacitor charges, it blocks DC, reducing steady-state loading compared with a plain shunt resistor.<\/p>\n<p>The match lasts only while the capacitor is charging. Too small a capacitor stops absorbing energy before the reflections settle. A larger one loads the line for longer, takes longer to recover, and draws more current during switching. The effective time constant depends on the impedances connected to the branch as well as its R and C values.<\/p>\n<p>Test isolated edges, the fastest repeating pattern, and the longest allowed runs of identical bits. A network that damps an isolated edge may respond differently after several transitions. In each case, check the receiver thresholds and sampling window. TI&#8217;s <a href=\"https:\/\/www.ti.com\/lit\/an\/snla034b\/snla034b.pdf\">comparison of differential termination techniques<\/a> covers these AC-network limitations alongside resistive alternatives.<\/p>\n<p>An AC termination branch connects from the load to its reference; it is not the same as a coupling capacitor inserted in the signal path. Do not substitute it for an interface-specified termination solely to reduce DC power.<\/p><h2 id=\"differential\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Is_Termination_Different_for_Differential_Pairs\"><\/span>How Is Termination Different for Differential Pairs?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A differential terminator matches the impedance seen between the two conductors.<\/strong> For a point-to-point LVDS link, a common implementation is one resistor across the receiver inputs. Its value follows the specified differential impedance and the receiver requirements.<\/p>\n<p>Do not assume every differential pair needs 100 \u03a9. Some receivers already have a switchable internal resistor, while some buses need termination at both physical ends. Adding an external 100 \u03a9 resistor across an enabled internal resistor of the same value gives a load of about 50 \u03a9, which can reduce the differential swing and overload the transmitter.<\/p>\n<p>Place an external cross-pair resistor near the receiving pins with balanced connections. A resistor across the pair terminates the differential mode; it does not independently establish a common-mode bias or correct asymmetric routing. Split or biased terminations must follow the interface circuit rather than a generic substitution.<\/p>\n<p>Analog Devices&#8217; <a href=\"https:\/\/www.analog.com\/en\/resources\/app-notes\/an-1177.html\">LVDS and M-LVDS implementation guide<\/a> explains how point-to-point and multipoint layouts differ. Identify the physical line ends and allowed stubs before choosing the network; counting receivers alone is not enough.<\/p><h2 id=\"resistor-values\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Do_You_Calculate_Termination_Resistor_Values\"><\/span>How Do You Calculate Termination Resistor Values?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Start with the impedance match, then simulate nearby resistor values using the actual driver and trace.<\/strong> For series termination, subtract the driver&#8217;s effective output impedance:<\/p>\n<p class=\"formula\" style=\"font-family:Cambria,Georgia,serif;font-size:22px;font-weight:700;margin:22px 0;background:none;\">R<sub>S<\/sub> \u2248 Z<sub>0<\/sub> \u2212 Z<sub>driver<\/sub><\/p>\n<p><strong>Worked example:<\/strong> assume a one-way point-to-point line, nominal Z<sub>0<\/sub> = 50 \u03a9, estimated driver impedance = 18 \u03a9, and one high-impedance receiver. The starting resistor is 50 \u2212 18 = <strong>32 \u03a9<\/strong>. These are calculation assumptions, not measured board data.<\/p>\n<p>Try 27 \u03a9, 30 \u03a9, 33 \u03a9, and 36 \u03a9 in simulation. With the assumed driver, the total source resistances are 45 \u03a9, 48 \u03a9, 51 \u03a9, and 54 \u03a9. The 33 \u03a9 resistor is closest to the nominal match; the simulations will show whether it also gives enough voltage and timing margin.<\/p>\n<ul><li><strong>Model the driver:<\/strong> use the vendor&#8217;s validated IBIS model with the intended I\/O settings. Check pull-up and pull-down behavior over process, voltage, and temperature; the assumed 18 \u03a9 will not remain constant.<\/li>\n<li><strong>Vary the channel:<\/strong> include the specified impedance tolerance, receiver capacitance, resistor tolerance, packages, and vias. Compare the worst overshoot, undershoot, and settling time for each resistor.<\/li>\n<li><strong>Check the sampling point:<\/strong> reject values that cause extra threshold crossings or leave insufficient setup\/hold margin. Choose a range that works across the tested conditions, rather than the value with the smoothest nominal waveform.<\/li><\/ul>\n<p>For a parallel resistor, start near Z<sub>0<\/sub> and verify output current and loaded logic levels. For Thevenin termination, solve resistance and bias together. An AC branch also needs a capacitor chosen for the transient and pattern constraints. The device specification takes priority where it prescribes values or calibrated on-die termination.<\/p><h2 id=\"placement\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"Where_Should_Termination_Resistors_Be_Placed\"><\/span>Where Should Termination Resistors Be Placed?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Place source termination next to the driver and load termination next to the receiver or physical line end.<\/strong> Keep the unmatched copper segment short enough that its delay is small relative to the signal edge. The allowable distance depends on edge rate and stackup, so there is no universal millimeter limit.<\/p>\n<ul><li><strong>Series network:<\/strong> route the output pin directly to the resistor, then continue with the main controlled-impedance trace. If the resistor cannot sit close to the pin, include that connecting segment in the simulation.<\/li>\n<li><strong>Parallel, Thevenin, or AC network:<\/strong> place the branch at the line end, with short connections to the receiver and reference. A long trace leading off to the resistor creates another segment that can reflect.<\/li>\n<li><strong>Differential or bidirectional link:<\/strong> preserve balanced pair connections and identify the physical ends. Follow the bus topology when either device can transmit.<\/li><\/ul>\n<p>Include pad expansions, neck-downs, return vias, and plane changes around the resistor in the channel model. The schematic treats the resistor as a lumped component, but its pads and connecting copper also affect the signal.<\/p><figure style=\"width:100%;max-width:600px;margin:32px auto;box-sizing:border-box;\"><img decoding=\"async\" src=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/09\/termination-placement-v2.jpg\" width=\"600\" height=\"900\" alt=\"Transmission line termination techniques, resistor placement at the source and receiver with an unwanted long branch for comparison.\" style=\"display:block;width:100%;max-width:600px;height:auto;margin:0 auto;\" loading=\"lazy\"><\/figure><h2 id=\"manufacturing\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Do_Controlled_Impedance_and_PCB_Manufacturing_Affect_Termination\"><\/span>How Do Controlled Impedance and PCB Manufacturing Affect Termination?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A terminator must match the impedance of the manufactured trace, not just the nominal design value.<\/strong> Trace width, etched conductor shape, copper thickness, dielectric spacing, material Dk, and solder mask all affect impedance. Vias and reference-plane transitions add local discontinuities.<\/p>\n<p>Consider a fixed 50 \u03a9 load on a hypothetical line spanning 45\u201355 \u03a9. At 45 \u03a9, \u0393<sub>L<\/sub> = 5 \/ 95 \u2248 +5.3%; at 55 \u03a9, \u0393<sub>L<\/sub> = \u22125 \/ 105 \u2248 \u22124.8%. These are voltage-reflection coefficients for a single ideal resistive boundary, not measured overshoot or a board acceptance limit. They show why a nominal match still needs a tolerance analysis.<\/p>\n<p>Before releasing the layout, agree on the <a href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/08\/impedance-control-pcb-2\/\">controlled-impedance stackup and verification requirements<\/a>: signal and reference layers, target impedance and tolerance, finished geometry, and a representative coupon. If the fabricator changes the dielectric or trace geometry, update the channel model and recheck the termination values.<\/p>\n<p>A coupon TDR measurement checks that coupon&#8217;s impedance under the recorded test conditions. It cannot establish the timing of a complete route through connectors, vias, and loads. Use channel measurements to locate discontinuities, and check the powered receiver waveform separately. Keep the stackup revision, coupon identity, fixture details, and measurement conditions with the results so they can be compared with the simulation.<\/p>\n<p>Fix a broken return path or long branch before tuning the resistor. Otherwise, a waveform that looks acceptable at one driver setting may fail when the load or temperature changes.<\/p><h2 id=\"mistakes\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"What_Are_the_Most_Common_Termination_Mistakes\"><\/span>What Are the Most Common Termination Mistakes?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A resistor that matches the schematic may still perform poorly on the board.<\/strong> These symptoms help narrow down what to check:<\/p>\n<ul><li><strong>A familiar resistor value still rings:<\/strong> confirm the current stackup and I\/O drive setting. Reusing 22 \u03a9 or 33 \u03a9 from another board does not establish the same source impedance.<\/li>\n<li><strong>A low-frequency clock double-triggers:<\/strong> inspect its edge rate and receiver threshold crossings. Repetition rate alone does not rule out transmission-line behavior.<\/li>\n<li><strong>The edge becomes too slow:<\/strong> include driver impedance in the source match and check receiver capacitance. Adding a full Z<sub>0<\/sub> resistor can introduce excessive source resistance.<\/li>\n<li><strong>Ringing remains despite a correct resistor:<\/strong> inspect the physical connection and probe setup. A long termination stub or probe ground lead can undermine the expected result.<\/li>\n<li><strong>Differential swing falls after assembly:<\/strong> check internal-termination settings and external population. Unintended parallel resistors may halve the intended load.<\/li>\n<li><strong>Typical simulation passes but hardware fails:<\/strong> compare model settings, actual geometry, supply conditions, and measurement loading. Retest operating corners before changing the resistor by trial and error.<\/li><\/ul><h2 id=\"selection\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"How_Do_You_Choose_the_Right_Transmission_Line_Termination_Technique\"><\/span>How Do You Choose the Right Transmission Line Termination Technique?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>The right network keeps the receiver within its voltage and timing limits without overloading the driver.<\/strong> Work through the circuit in this order:<\/p>\n<ol><li><strong>Check whether termination is needed.<\/strong> Compare the fastest edge with the channel delay, then check the unterminated waveform against the receiver limits. This shows whether the route needs further termination analysis; clock frequency alone cannot answer that question.<\/li>\n<li><strong>Check the topology and interface requirements.<\/strong> Mark the sources, receivers, physical line ends, and internal termination. Use the device documentation to identify which external networks are allowed and where they connect.<\/li>\n<li><strong>Choose a network and calculate starting values.<\/strong> Decide whether the circuit needs source matching, load matching, a bias voltage, or temporary loading. Calculate the resistance and driver current, together with any bias or RC requirements.<\/li>\n<li><strong>Simulate the routed board.<\/strong> Vary component values and operating conditions with the actual resistor placement, vias, and other discontinuities included. Keep the networks that meet the receiver&#8217;s voltage, threshold-crossing, and timing limits.<\/li>\n<li><strong>Measure the prototype.<\/strong> Probe the receiver node with a suitable low-loading probe and compare the waveform with the simulation. Resolve any disagreement before finalizing the production BOM and I\/O settings.<\/li><\/ol>\n<p>Keep the selected parts and I\/O settings with the stackup revision, model versions, acceptance limits, and measured or simulated margins. After a layout or component change, these records show which assumptions need to be checked again.<\/p><h2 id=\"faq\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"FAQs_About_Transmission_Line_Termination\"><\/span>FAQs About Transmission Line Termination<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"faq-question\"><strong>Q1: Should you terminate both ends of a transmission line?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A1:<\/strong> It depends on the interface and direction of transmission. Some bidirectional buses terminate at both physical ends; a one-way source-terminated point-to-point net typically uses a high-impedance far end. Adding a second network changes the loading and must be modeled.<\/p>\n<p class=\"faq-question\"><strong>Q2: Does DDR use the same termination on every signal?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A2:<\/strong> No. Data, strobes, clocks, and command\/address signals can use different topologies and termination schemes. Follow the controller and memory generation&#8217;s routing rules and on-die termination settings; a generic 50 \u03a9 or 100 \u03a9 recommendation is insufficient.<\/p>\n<p class=\"faq-question\"><strong>Q3: What if driver impedance is already higher than Z<sub>0<\/sub>?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A3:<\/strong> A negative result from Z<sub>0<\/sub> \u2212 Z<sub>driver<\/sub> means a positive series resistor cannot create the desired source match. Recheck the model and permitted drive settings, then simulate another valid circuit rather than adding resistance automatically.<\/p>\n<p class=\"faq-question\"><strong>Q4: Must a termination resistor match 50 \u03a9 exactly?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A4:<\/strong> First verify that 50 \u03a9 is the correct target. The accepted resistor value depends on the termination type, device impedance, tolerance, and required margin. A nominally exact resistor cannot correct an incorrect stackup or a large local discontinuity.<\/p>\n<p class=\"faq-question\"><strong>Q5: How close is close enough to the pin?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A5:<\/strong> Use any device-specific layout limit first. Otherwise, model the segment between the pin and termination relative to the fastest edge. A fixed distance such as 5 mm is not universally safe across different edge rates and stackups.<\/p>\n<p class=\"faq-question\"><strong>Q6: Should you add optional termination footprints?<\/strong><\/p>\n<p class=\"faq-answer\"><strong>A6:<\/strong> They can make prototype tuning easier if placed at the correct boundary. Include the pads and unused branch geometry in the model, and document which parts are fitted so assembly does not create unintended double termination.<\/p><h2 id=\"conclusion\" style=\"word-break:normal!important;overflow-wrap:normal!important;margin:40px 0 18px;padding-left:16px;font-size:clamp(24px,3.5vw,32px);line-height:1.3;text-align:left;\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Start with the interface requirements and signal path, calculate the initial component values, then test the routed board. A nominal impedance match is only the starting point: the receiver must still see valid voltage levels and enough timing margin under the expected operating conditions.<\/p>\n<p>Need a controlled-impedance PCB or assembly quote? Send <a href=\"mailto:sales@bestpcbs.com\">EBest Circuit<\/a> your Gerber or ODB++ files, proposed stackup, signal layers, impedance targets and tolerances, quantity, and required delivery date. Request a free DFM review and include any coupon and test-report requirements. For assembly, also send the BOM, placement data, and a clear list of which optional termination parts should be fitted.<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The main transmission line termination techniques in PCB design are series, parallel, Thevenin, and AC termination. Series termination matches the source; the other three place a terminating network at the load. The choice depends on where reflections occur, how much current the driver can supply, and how quickly the receiver must reach a valid logic [&hellip;]<\/p>\n","protected":false},"author":33247,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"categories":[5789],"tags":[6904,156,8099,8101,8100],"class_list":["post-34995","post","type-post","status-publish","format-standard","hentry","category-pcb-design","tag-controlled-impedance","tag-high-speed-pcb-design","tag-signal-integrity","tag-termination-resistors","tag-transmission-line-termination"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Jessica, Jessica\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"What Are the Main Transmission Line Termination Techniques?\" \/>\n\t\t<meta property=\"og:description\" content=\"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-09-02T10:24:11+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-02T10:24:13+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Bestpcbs1\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:title\" content=\"What Are the Main Transmission Line Termination Techniques?\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@bestpcbs\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#blogposting\",\"name\":\"What Are the Main Transmission Line Termination Techniques?\",\"headline\":\"What Are the Main Transmission Line Termination Techniques?\",\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/jessica\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/termination-techniques-overview-v2.jpg\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#articleImage\",\"width\":600,\"height\":501,\"caption\":\"Transmission line termination techniques, series at the source and parallel, Thevenin, or AC at the load.\"},\"datePublished\":\"2026-09-02T18:24:11+08:00\",\"dateModified\":\"2026-09-02T18:24:13+08:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#webpage\"},\"articleSection\":\"PCB Design, controlled impedance, high-speed pcb design, Signal Integrity, Termination Resistors, Transmission Line Termination\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/pcb-design\\\/#listItem\",\"name\":\"PCB Design\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/pcb-design\\\/#listItem\",\"position\":2,\"name\":\"PCB Design\",\"item\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/pcb-design\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#listItem\",\"name\":\"What Are the Main Transmission Line Termination Techniques?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#listItem\",\"position\":3,\"name\":\"What Are the Main Transmission Line Termination Techniques?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/category\\\/pcb-design\\\/#listItem\",\"name\":\"PCB Design\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"telephone\":\"+8675529091601\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/logo.png\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Bestpcbs1\",\"https:\\\/\\\/twitter.com\\\/bestpcbs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCJsTR02i6mtLFnBBNC_i4bQ\\\/featured\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/best-pcb-technology\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/jessica\\\/#author\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/jessica\\\/\",\"name\":\"Jessica, Jessica\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5c4fd158c0480577de347b49ba974e2a?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Jessica, Jessica\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#webpage\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/\",\"name\":\"What Are the Main Transmission Line Termination Techniques?\",\"description\":\"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/2026\\\/09\\\/transmission-line-termination-techniques\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/jessica\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/author\\\/jessica\\\/#author\"},\"datePublished\":\"2026-09-02T18:24:11+08:00\",\"dateModified\":\"2026-09-02T18:24:13+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/\",\"name\":\"PCB & MCPCB - Best Technology\",\"description\":\"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bestpcbs.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"What Are the Main Transmission Line Termination Techniques?","description":"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.","canonical_url":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#blogposting","name":"What Are the Main Transmission Line Termination Techniques?","headline":"What Are the Main Transmission Line Termination Techniques?","author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/jessica\/#author"},"publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2026\/09\/termination-techniques-overview-v2.jpg","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#articleImage","width":600,"height":501,"caption":"Transmission line termination techniques, series at the source and parallel, Thevenin, or AC at the load."},"datePublished":"2026-09-02T18:24:11+08:00","dateModified":"2026-09-02T18:24:13+08:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#webpage"},"isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#webpage"},"articleSection":"PCB Design, controlled impedance, high-speed pcb design, Signal Integrity, Termination Resistors, Transmission Line Termination"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog#listItem","position":1,"name":"Home","item":"https:\/\/www.bestpcbs.com\/blog","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/#listItem","name":"PCB Design"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/#listItem","position":2,"name":"PCB Design","item":"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#listItem","name":"What Are the Main Transmission Line Termination Techniques?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#listItem","position":3,"name":"What Are the Main Transmission Line Termination Techniques?","previousItem":{"@type":"ListItem","@id":"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/#listItem","name":"PCB Design"}}]},{"@type":"Organization","@id":"https:\/\/www.bestpcbs.com\/blog\/#organization","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","url":"https:\/\/www.bestpcbs.com\/blog\/","telephone":"+8675529091601","logo":{"@type":"ImageObject","url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#organizationLogo"},"image":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/Bestpcbs1","https:\/\/twitter.com\/bestpcbs","https:\/\/www.youtube.com\/channel\/UCJsTR02i6mtLFnBBNC_i4bQ\/featured","https:\/\/www.linkedin.com\/company\/best-pcb-technology"]},{"@type":"Person","@id":"https:\/\/www.bestpcbs.com\/blog\/author\/jessica\/#author","url":"https:\/\/www.bestpcbs.com\/blog\/author\/jessica\/","name":"Jessica, Jessica","image":{"@type":"ImageObject","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/5c4fd158c0480577de347b49ba974e2a?s=96&d=mm&r=g","width":96,"height":96,"caption":"Jessica, Jessica"}},{"@type":"WebPage","@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#webpage","url":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/","name":"What Are the Main Transmission Line Termination Techniques?","description":"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/#breadcrumblist"},"author":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/jessica\/#author"},"creator":{"@id":"https:\/\/www.bestpcbs.com\/blog\/author\/jessica\/#author"},"datePublished":"2026-09-02T18:24:11+08:00","dateModified":"2026-09-02T18:24:13+08:00"},{"@type":"WebSite","@id":"https:\/\/www.bestpcbs.com\/blog\/#website","url":"https:\/\/www.bestpcbs.com\/blog\/","name":"PCB & MCPCB - Best Technology","description":"More Technical Details & News on PCB, MCPCB & Ceramic PCB from EBest PCB","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.bestpcbs.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"PCB &amp; MCPCB - EBest PCB - More Technical Details &amp; News on PCB, MCPCB &amp; Ceramic PCB from EBest PCB","og:type":"article","og:title":"What Are the Main Transmission Line Termination Techniques?","og:description":"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.","og:url":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/","og:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","og:image:secure_url":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2025\/08\/logo.png","article:published_time":"2026-09-02T10:24:11+00:00","article:modified_time":"2026-09-02T10:24:13+00:00","article:publisher":"https:\/\/www.facebook.com\/Bestpcbs1","twitter:card":"summary_large_image","twitter:site":"@bestpcbs","twitter:title":"What Are the Main Transmission Line Termination Techniques?","twitter:description":"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.","twitter:creator":"@bestpcbs","twitter:image":"https:\/\/www.bestpcbs.com\/blog\/wp-content\/uploads\/2016\/02\/logo.gif"},"aioseo_meta_data":{"post_id":"34995","title":"What Are the Main Transmission Line Termination Techniques?","description":"Compare transmission line termination techniques, calculate resistor values, avoid placement errors, and check impedance tolerances in PCB design.","keywords":null,"keyphrases":{"focus":{"keyphrase":"transmission line termination techniques","score":78,"analysis":{"keyphraseInTitle":{"score":9,"maxScore":9,"error":0},"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":4},"keyphraseInURL":{"score":5,"maxScore":5,"error":0},"keyphraseInIntroduction":{"score":9,"maxScore":9,"error":0},"keyphraseInSubHeadings":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":{"score":9,"maxScore":9,"error":0},"keywordDensity":{"score":0,"type":"low","maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-09-02 07:20:49","updated":"2026-09-02 10:48:19","seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/\" title=\"PCB Design\">PCB Design<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tWhat Are the Main Transmission Line Termination Techniques?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.bestpcbs.com\/blog"},{"label":"PCB Design","link":"https:\/\/www.bestpcbs.com\/blog\/category\/pcb-design\/"},{"label":"What Are the Main Transmission Line Termination Techniques?","link":"https:\/\/www.bestpcbs.com\/blog\/2026\/09\/transmission-line-termination-techniques\/"}],"_links":{"self":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/34995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/users\/33247"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/comments?post=34995"}],"version-history":[{"count":7,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/34995\/revisions"}],"predecessor-version":[{"id":35037,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/posts\/34995\/revisions\/35037"}],"wp:attachment":[{"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/media?parent=34995"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/categories?post=34995"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bestpcbs.com\/blog\/wp-json\/wp\/v2\/tags?post=34995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}